Skip to main content
Blue Stripe · Metric PE100 AS/NZS 4130 Measured by Outside Diameter (OD)

DN20 Metric PE100 PN8 (SDR21, Blue Stripe) — 300m Friction Loss Chart & Calculator

OD-measured 20 mm Metric PE100 (AS/NZS 4130, SDR21 nominal). AS/NZS 4130 minimum wall floor of 1.6 mm applies to DN20 SDR21/17/13.6, yielding 16.6 mm mean ID—significantly narrower than 3/4" Rural Class B (19.1 mm ID). Uses metric 20 mm external compression fittings.

Switch Run Length (DN20 PE100 PN8)
Other DN20 Pressure Classes (300m)
True Mean ID
16.6 mm
Outside Dia (OD)
20 mm
Wall Thickness
1.6 mm SDR21
PN Rating (20°C)
800 kPa 82 m max · 680 kPa warn
Derated (40°C)
592 kPa 74% AS/NZS 4130 (60 m)
Safe Flow ≤1.5 m/s
19 L/min Hammer >31 L/min
Fitting System
External Full-Bore Metric Compression / Electrofusion
Zero-JS Engineering Reference Table · 20°C Water

DN20 PE100 PN8 Friction Loss & Velocity Chart over 300 Metres

ID: 16.6 mm · ε = 0.0015 mm · Hazen-Williams C = 150

Flow (L/min) Flow (L/hr) Velocity (m/s) Darcy Head (300m) Darcy Drop (kPa) Hazen-W C=150 (m) Drop (PSI) Safety Status
10 600 0.77 15.93 m 156.2 kPa 14.02 m 22.7 psi Safe (≤1.5 m/s)
15 900 1.16 32.42 m 318.0 kPa 29.71 m 46.1 psi Safe (≤1.5 m/s)
20 1,200 1.54 53.85 m 528.1 kPa 50.62 m 76.6 psi Caution (1.5–2.4 m/s)
25 1,500 1.93 79.96 m 784.1 kPa 76.52 m 113.7 psi Caution (1.5–2.4 m/s)
30 1,800 2.31 110.56 m 1084.3 kPa >PN 107.26 m 157.3 psi Caution (1.5–2.4 m/s)
35 2,100 2.70 145.53 m 1427.2 kPa >PN 142.70 m 207.0 psi Water Hammer (>2.4 m/s)
38 2,280 2.93 168.56 m 1653.0 kPa >PN 166.18 m 239.8 psi Water Hammer (>2.4 m/s)

Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.

Blue Stripe · Metric PE100AS/NZS 4130 · OD-Measured

Interactive DN20 PE100 PN8 (300m) Pump & Friction Solver

Pre-loaded with 300 m of DN20 Metric PE100 PN8 (SDR21, Blue Stripe) (16.6 mm ID) at 15 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.

1. Pipe Standard & Size

44 AU Specs
Measured By
OD (Outer)
True Bore ID
16.6 mm
Outside OD
20 mm
Max @ 20°C
800 kPa

OD-measured 20 mm Metric PE100 (AS/NZS 4130, SDR21 nominal). AS/NZS 4130 minimum wall floor of 1.6 mm applies to DN20 SDR21/17/13.6, yielding 16.6 mm mean ID—significantly narrower than 3/4" Rural Class B (19.1 mm ID). Uses metric 20 mm external compression fittings.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 900 L/hr · 21,600 L/24h

1 × 200 m coil + 1 × 100 m coil
m
+98 kPa uphill
m
Total Suction: 1.81 m / 5.5 m max
m
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (6)

ΣK = 9.60 · +7.0 m eq. pipe · 0.65 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

Loss: 0.31 m (3.0 kPa · +3.3 m eq.)

1

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DDifferent fitting systemInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

0
Rural Barbed 90° ElbowK=1.9 · 85DDifferent fitting systemInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

0
Rural Barbed Tee (Branch)K=2.4 · 110DDifferent fitting systemInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12D

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

Loss: 0.02 m (0.2 kPa · +0.2 m eq.)

1
Metric Compression 90° ElbowK=0.75 · 32D

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

Loss: 0.10 m (1.0 kPa · +1.1 m eq.)

2
Metric Compression Tee (Branch)K=1.2 · 55D

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

Loss: 0.22 m (2.1 kPa · +2.3 m eq.)

1

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.1 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (DN20 PE100 PN8) and active pump category (Solar Bore Pump (24V/48V)).

Solar Bore SpecialistQuote Partner

Off-Grid Solar Bore Kits Sized to Your Total Dynamic Head

Compare 24V/48V brushless submersible kits matched to your calculated head, flow rate, and poly drop-pipe.

Get Matched Solar Bore Pump Packages
AS/NZS 4130 PE100AU Supplier

AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings

Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.

Price 300m of DN20 PE100 PN8 + Compression Fittings

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Engineering Q&A: DN20 PE100 PN8 over 300 Metres

What is the maximum safe flow rate for DN20 PE100 PN8 (16.6 mm ID)?

For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN20 Metric PE100 PN8 (SDR21, Blue Stripe) (16.6 mm true internal diameter) safely carries up to 19.5 L/min (1,169 L/hr). Above 31.2 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.

How much friction head loss does 300m of DN20 PE100 PN8 have at 15 L/min?

Over a 300 m run at 15 L/min (velocity 1.16 m/s, 20°C water), DN20 PE100 PN8 loses 32.42 m of head (318 kPa / 46.1 PSI) via Darcy-Weisbach, compared with 29.71 m using Hazen-Williams (C=150).

What is the maximum pressure rating of DN20 PE100 PN8 in hot Australian summer conditions?

DN20 Metric PE100 PN8 (SDR21, Blue Stripe) is rated to 800 kPa maximum (81.6 m head; 680 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 592 kPa (60.4 m head).

How does DN20 PE100 PN8 compare to 3/4" Rural Class B in Australia?

3/4" Rural Class B is measured by Internal Diameter (19.1 mm ID) while DN20 PE100 PN8 is measured by Outside Diameter (20 mm OD, leaving 16.6 mm true ID). At 15 L/min over 300 m, the narrower Metric bore experiences 1.95× the friction loss (+15.8 m / +155 kPa), and Rural vs Metric fittings are physically incompatible.