DN20 Metric PE100 PN16 (SDR11, Blue Stripe) — 300m Friction Loss Chart & Calculator
High-pressure 1600 kPa OD-measured DN20 Metric PE100 (AS/NZS 4130, SDR11). Thick 1.9 mm wall reduces bore to 16.0 mm—best reserved for short potable house service connections and high-pressure taps where flow stays below ~20 L/min.
- True Mean ID
- 16 mm
- Outside Dia (OD)
- 20 mm
- Wall Thickness
- 1.9 mm SDR11
- PN Rating (20°C)
- 1600 kPa 163 m max · 1360 kPa warn
- Derated (40°C)
- 1184 kPa 74% AS/NZS 4130 (121 m)
- Safe Flow ≤1.5 m/s
- 18 L/min Hammer >29 L/min
- Fitting System
- External Full-Bore Metric Compression / Electrofusion
DN20 PE100 PN16 Friction Loss & Velocity Chart over 300 Metres
ID: 16 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (300m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.83 | 18.98 m | 186.1 kPa | 16.78 m | 27.0 psi | Safe (≤1.5 m/s) |
| 15 | 900 | 1.24 | 38.64 m | 379.0 kPa | 35.55 m | 55.0 psi | Safe (≤1.5 m/s) |
| 20 | 1,200 | 1.66 | 64.21 m | 629.7 kPa | 60.56 m | 91.3 psi | Caution (1.5–2.4 m/s) |
| 25 | 1,500 | 2.07 | 95.36 m | 935.2 kPa | 91.55 m | 135.6 psi | Caution (1.5–2.4 m/s) |
| 30 | 1,800 | 2.49 | 131.90 m | 1293.5 kPa | 128.32 m | 187.6 psi | Water Hammer (>2.4 m/s) |
| 35 | 2,100 | 2.90 | 173.66 m | 1703.0 kPa >PN | 170.72 m | 247.0 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
Step up to DN25 PE100 PN16 & cut friction by 67.0%
Stepping up from DN20 PE100 PN16 (16 mm ID) to DN25 PE100 PN16 (20.2 mm ID) cuts pipe friction by 67.0% (saving 25.9 m / 254 kPa) and lowers velocity from 1.24 to 0.78 m/s.
Don’t confuse DN20 PE100 PN16 (16 mm ID) with 3/4" Rural Class B (19.1 mm ID)
DN20 PE100 PN16 (16 mm ID) has a 3.1 mm smaller bore than 3/4" Rural Class B (19.1 mm ID), causing 2.32× the pipe friction loss (+22.0 m / +216 kPa) and reducing 240V Tank Jet Pump flow by 5.7 L/min (35.1%).
DN20 PE100 PN16 vs Next Size Up (DN25 PE100 PN16) — 300 m Run
Length: 300 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive DN20 PE100 PN16 (300m) Pump & Friction Solver
Pre-loaded with 300 m of DN20 Metric PE100 PN16 (SDR11, Blue Stripe) (16 mm ID) at 15 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsHigh-pressure 1600 kPa OD-measured DN20 Metric PE100 (AS/NZS 4130, SDR11). Thick 1.9 mm wall reduces bore to 16.0 mm—best reserved for short potable house service connections and high-pressure taps where flow stays below ~20 L/min.
2. Site Run & Hydraulic Conditions
Equivalent: 900 L/hr · 21,600 L/24h
3. Fittings & Valves (6)
ΣK = 9.60 · +6.8 m eq. pipe · 0.76 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.35 m (3.5 kPa · +3.2 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
Loss: 0.02 m (0.2 kPa · +0.2 m eq.)
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Loss: 0.12 m (1.2 kPa · +1.0 m eq.)
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Loss: 0.25 m (2.5 kPa · +2.2 m eq.)
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.1 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.24 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (599 kPa) is safely within DN20 PE100 PN16 working rating (1360 kPa warning / 1600 kPa max).
Total suction head is 1.85 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
3/4" Rural Class B vs. DN20 PE100 PN16
DN20 PE100 PN16 (16 mm ID) has a 3.1 mm smaller bore than 3/4" Rural Class B (19.1 mm ID), causing 2.32× the pipe friction loss (+22.0 m / +216 kPa) and reducing Solar Bore Pump (24V/48V) flow by 7.8 L/min (32.4%).
Step Up to DN25 PE100 PN16
Stepping up from DN20 PE100 PN16 (16 mm ID) to DN25 PE100 PN16 (20.2 mm ID) cuts pipe friction by 67.0% (saving 25.9 m / 254 kPa) and lowers velocity from 1.24 to 0.78 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 300 m DN20 PE100 PN16 system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
Solar Bore Pump (24V/48V)Active Strong match: delivers 16.2 L/min at 67.0 m head (1.35 m/s) safely within pipe pressure limits. | Solar DC | 16.2 L/min @ 67.0 m 657 kPa · 1.35 m/s | 75 m (735 kPa) | Recommended Match | $1,400–$3,200 AUD | |
Single-Impeller Fire Pump Meets target flow at 16.6 L/min (69.0 m head), but note: very low flow on pump curve. | Petrol | 16.6 L/min @ 69.0 m 677 kPa · 1.38 m/s | 70 m (686 kPa) | Capable (Check Sizing) | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Meets target flow at 21.5 L/min (96.1 m head), but note: very low flow on pump curve. | Petrol | 21.5 L/min @ 96.1 m 943 kPa · 1.78 m/s | 98 m (961 kPa) | Capable (Check Sizing) | $850–$1,650 AUD | |
240V Multistage Irrigation Pump Delivers 14.8 L/min (99% of 15 L/min target) at 60.2 m head. | 240V AC | 14.8 L/min @ 60.2 m 590 kPa · 1.23 m/s | 62 m (608 kPa) | Undersized Flow | $650–$1,450 AUD | |
240V Tank Jet Pump Delivers 10.5 L/min (70% of 15 L/min target) at 42.8 m head. | 240V AC | 10.5 L/min @ 42.8 m 420 kPa · 0.87 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD | |
2" Trash / Transfer Pump Delivers 5.2 L/min (35% of 15 L/min target) at 27.9 m head. | Petrol | 5.2 L/min @ 27.9 m 274 kPa · 0.43 m/s | 28 m (275 kPa) | Undersized Flow | $450–$980 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
+ 1 straight coil-to-coil joiner recommended to connect rolls.
Use AS/NZS 4130 Metric DN20 (20 mm OD) external compression or electrofusion fittings. Rural barbed insert fittings will NOT match this pipe's 16 mm bore.
- 1 × 24V / 48V Brushless Solar Submersible Bore Pump$1,400–$3,200 AUDInlet 100 mm / Outlet 32 mm · Shut-off 75 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.35 m
- 2 × Metric PE100 External Compression 90° ElbowK=1.50 · 0.12 m
- 1 × Metric PE100 External Compression JoinerK=0.25 · 0.02 m
- 1 × Spring-Loaded Brass / Stainless Check ValveK=3.20 · 0.25 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (DN20 PE100 PN16) and active pump category (Solar Bore Pump (24V/48V)).
Off-Grid Solar Bore Kits Sized to Your Total Dynamic Head
Compare 24V/48V brushless submersible kits matched to your calculated head, flow rate, and poly drop-pipe.
AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings
Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: DN20 PE100 PN16 over 300 Metres
What is the maximum safe flow rate for DN20 PE100 PN16 (16 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN20 Metric PE100 PN16 (SDR11, Blue Stripe) (16 mm true internal diameter) safely carries up to 18.1 L/min (1,086 L/hr). Above 29.0 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 300m of DN20 PE100 PN16 have at 15 L/min?
Over a 300 m run at 15 L/min (velocity 1.24 m/s, 20°C water), DN20 PE100 PN16 loses 38.64 m of head (379 kPa / 55.0 PSI) via Darcy-Weisbach, compared with 35.55 m using Hazen-Williams (C=150).
What is the maximum pressure rating of DN20 PE100 PN16 in hot Australian summer conditions?
DN20 Metric PE100 PN16 (SDR11, Blue Stripe) is rated to 1600 kPa maximum (163.2 m head; 1360 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 1184 kPa (120.7 m head).
How does DN20 PE100 PN16 compare to 3/4" Rural Class B in Australia?
3/4" Rural Class B is measured by Internal Diameter (19.1 mm ID) while DN20 PE100 PN16 is measured by Outside Diameter (20 mm OD, leaving 16 mm true ID). At 15 L/min over 300 m, the narrower Metric bore experiences 2.32× the friction loss (+22.0 m / +216 kPa), and Rural vs Metric fittings are physically incompatible.