3/4" Rural Poly vs 20mm Metric Poly (DN20 PN12.5): Friction Loss & Bore Comparison
3/4" Rural delivers 32% more bore area and ~50% lower friction than DN20 PE100 PN12.5
Under AS/NZS 4130, DN20 Metric PE100 PN12.5 has a 20.0 mm OD and a 1.6 mm minimum wall floor leaving just 16.6 mm ID—whereas 3/4" Rural Class B has a full 19.1 mm ID (22.5 mm OD). Beyond 50m at 25–30 L/min, DN20 loses steep pressure; step up to DN25 PE100 (21.0 mm ID) for pressurised domestic runs.
3/4" Rural Class B vs. DN20 PE100 PN12.5 Specification Table
| Engineering Specification | 3/4" Rural Class B | DN20 PE100 PN12.5 | Engineering Impact |
|---|---|---|---|
| Australian Standard | AS 2698.2 | AS/NZS 4130 | ID-measured vs OD-measured |
| True Internal Diameter (ID) | 19.1 mm | 16.6 mm | 3/4" Rural Class B is +2.5 mm wider |
| Outside Diameter (OD) | 22.5 mm | 20 mm | External compression fittings will NOT interchange |
| Wall Thickness | 1.7 mm | 1.6 mm (SDR13.6) | 3/4" Rural Class B wall is +0.1 mm thicker |
| Cross-Sectional Bore Area | 287 mm² | 216 mm² | 3/4" Rural Class B holds +32.4% larger bore area |
| Max Safe Flow (≤1.5 m/s) | 25.8 L/min | 19.5 L/min | Water hammer warning begins above 2.4 m/s |
| PN Rating (20°C / 40°C) | 800 / 592 kPa | 1250 / 925 kPa | DN20 PE100 PN12.5 gives +450 kPa pressure headroom |
| Fitting System | Rural Barbed Insert / Rural Compression | External Full-Bore Metric Compression | External metric compression fittings cut elbow/joiner K-factor by >50% |
100m & 200m Friction Loss, Velocity & Pressure Penalty
| Flow (L/min) | 3/4" Rural Class B Vel | DN20 PE100 PN12.5 Vel | 100m: 3/4" Rural Class B | 100m: DN20 PE100 PN12.5 | 200m: 3/4" Rural Class B | 200m: DN20 PE100 PN12.5 | 200m Penalty / Ratio |
|---|---|---|---|---|---|---|---|
| 10 | 0.58 m/s | 0.77 m/s | 2.7 m (27 kPa) | 5.3 m (52 kPa) | 5.5 m (53 kPa) | 10.6 m (104 kPa) | +51 kPa (1.95×) |
| 15 | 0.87 m/s | 1.16 m/s | 5.5 m (54 kPa) | 10.8 m (106 kPa) | 11.1 m (109 kPa) | 21.6 m (212 kPa) | +103 kPa (1.95×) |
| 20 | 1.16 m/s | 1.54 m/s | 9.2 m (90 kPa) | 18.0 m (176 kPa) | 18.4 m (180 kPa) | 35.9 m (352 kPa) | +172 kPa (1.95×) |
| 25 | 1.45 m/s | 1.93 m/s | 13.6 m (134 kPa) | 26.7 m (261 kPa) | 27.3 m (267 kPa) | 53.3 m (523 kPa) | +255 kPa (1.96×) |
| 35 | 2.04 m/s | 2.70 m/s | 24.8 m (243 kPa) | 48.5 m (476 kPa) | 49.5 m (486 kPa) | 97.0 m (951 kPa) | +466 kPa (1.96×) |
| 45 | 2.62 m/s | 3.47 m/s | 38.8 m (380 kPa) | 76.1 m (746 kPa) | 77.5 m (760 kPa) | 152.1 m (1492 kPa) | +731 kPa (1.96×) |
System Head Curve: 3/4" Rural Class B vs DN20 PE100 PN12.5 (100 m)
Length: 100 m · Static Rise: 8 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
When to choose 3/4" Rural Class B (19.1 mm ID)
- Short paddock trough branch spurs and low-pressure gravity feeds under 630 kPa.
- Matching existing 3/4" rural barbed fittings on small rural blocks.
- Garden & orchard drip headers where flow stays below 25 L/min.
When to choose DN20 PE100 PN12.5 (16.6 mm ID)
- Short high-pressure potable tap connections, shed feeds, and town-water tie-ins requiring AS/NZS 4130 Blue Stripe.
- Pressurised lines above 630 kPa or buried potable lines needing 1,250 kPa certification.
- Low-flow feeds under 15–20 L/min over short distances (< 50 m).
Live Test: 3/4" Rural Class B vs DN20 PE100 PN12.5
Pre-loaded with 3/4" Rural Class B over 100 m at 25 L/min. Switch pipe or flow to test your exact farm elevation and pump curve.
1. Pipe Standard & Size
44 AU SpecsID-measured rural LDPE/MDPE poly (AS 2698.2 Green Stripe). True bore is 19.1 mm—2.5 mm wider than DN20 Metric PE100 PN12.5 (16.6 mm ID). Requires rural barbed or rural-sized compression fittings; standard metric DN20 fittings will NOT seal on the 22.5 mm OD. Rated 630 kPa recommended working / 800 kPa max at 20°C.
2. Site Run & Hydraulic Conditions
Equivalent: 1,500 L/hr · 36,000 L/24h
3. Fittings & Valves (5)
ΣK = 9.65 · +8.3 m eq. pipe · 1.04 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.49 m (4.8 kPa · +3.8 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
Loss: 0.13 m (1.3 kPa · +1.1 m eq.)
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Loss: 0.41 m (4.0 kPa · +3.2 m eq.)
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.02 m (0.2 kPa · +0.2 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.45 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (337 kPa) is safely within 3/4" Rural Class B working rating (630 kPa warning / 800 kPa max).
Total suction head is 1.99 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
3/4" Rural Class B vs. DN20 PE100 PN12.5
DN20 PE100 PN12.5 (16.6 mm ID) has a 2.5 mm smaller bore than 3/4" Rural Class B (19.1 mm ID), causing 1.96× the pipe friction loss (+13.0 m / +128 kPa) and reducing 240V Tank Jet Pump flow by 6.9 L/min (25.1%).
Step Up to 1" Rural Class B
Stepping up from 3/4" Rural Class B (19.1 mm ID) to 1" Rural Class B (25.3 mm ID) cuts pipe friction by 73.8% (saving 10.1 m / 99 kPa) and lowers velocity from 1.45 to 0.83 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 100 m 3/4" Rural Class B system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
240V Tank Jet PumpActive Strong match: delivers 27.4 L/min at 37.0 m head (1.60 m/s) safely within pipe pressure limits. | 240V AC | 27.4 L/min @ 37.0 m 363 kPa · 1.60 m/s | 46 m (451 kPa) | Recommended Match | $380–$780 AUD | |
Solar Bore Pump (24V/48V) Strong match: delivers 36.3 L/min at 48.3 m head (2.11 m/s) safely within pipe pressure limits. | Solar DC | 36.3 L/min @ 48.3 m 474 kPa · 2.11 m/s | 75 m (735 kPa) | Recommended Match | $1,400–$3,200 AUD | |
240V Multistage Irrigation Pump Meets target flow at 41.8 L/min (56.6 m head), but note: high velocity (2.43 m/s). | 240V AC | 41.8 L/min @ 56.6 m 555 kPa · 2.43 m/s | 62 m (608 kPa) | Capable (Check Sizing) | $650–$1,450 AUD | |
Single-Impeller Fire Pump Meets target flow at 48.0 L/min (67.1 m head), but note: high velocity (2.79 m/s), very low flow on pump curve. | Petrol | 48.0 L/min @ 67.1 m 658 kPa · 2.79 m/s | 70 m (686 kPa) | Capable (Check Sizing) | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Delivers 61.0 L/min at 92.7 m head, but shut-off pressure (961 kPa) exceeds 3/4" Rural Class B max rating (800 kPa). | Petrol | 61.0 L/min @ 92.7 m 909 kPa · 3.55 m/s | 98 m (961 kPa) Exceeds pipe max! | Overpressure Risk | $850–$1,650 AUD | |
2" Trash / Transfer Pump Delivers 17.9 L/min (72% of 25 L/min target) at 27.8 m head. | Petrol | 17.9 L/min @ 27.8 m 272 kPa · 1.04 m/s | 28 m (275 kPa) | Undersized Flow | $450–$980 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
Use AS 2698.2 Rural 3/4" ID-sized barbed insert fittings (with stainless cobra/worm-drive clamps) or Rural external compression fittings. Standard Metric OD fittings will NOT seal on this pipe's 22.5 mm OD.
- 1 × 240V Constant-Pressure Household & Rainwater Tank Jet Pump$380–$780 AUDInlet 25 mm / Outlet 25 mm · Shut-off 46 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.49 m
- 2 × Rural Poly Barbed 90° Insert ElbowK=3.80 · 0.41 m
- 1 × Rural Poly Barbed Insert JoinerK=1.20 · 0.13 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.02 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (3/4" Rural Class B) and active pump category (240V Tank Jet Pump).
240V Rainwater Tank Jet & Multistage Irrigation Pumps
Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.
AS 2698.2 Rural Poly Pipe & Matched Rural Fittings
Avoid the metric fitting trap—order ID-measured Green Stripe Class B or Red Line PN9 coils with rural compression or barbed joiners.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Technical Q&A: 3/4" Rural vs DN20 Metric PE100
What is the true internal diameter difference between 3/4" Rural Class B and DN20 PE100 PN12.5?
3/4" Rural Poly Pipe Class B (Green Stripe) has a 19.1 mm true internal bore (22.5 mm OD, ID-measured), whereas DN20 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) has a 16.6 mm true internal bore (20 mm OD, OD-measured)—a 2.5 mm diameter gap and 32.4% bore area difference in favour of 3/4" Rural Class B.
How much more friction loss occurs over 200m at 25 L/min?
At 25 L/min over 200 m, 3/4" Rural Class B loses 27.3 m (267 kPa) while DN20 PE100 PN12.5 loses 53.3 m (523 kPa)—meaning DN20 PE100 PN12.5 has 1.96× the friction loss of 3/4" Rural Class B (+255 kPa difference).
Are fittings interchangeable between 3/4" Rural Class B and DN20 PE100 PN12.5?
No—3/4" Rural Class B (22.5 mm OD, AS 2698.2) and DN20 PE100 PN12.5 (20 mm OD, AS/NZS 4130) are physically incompatible. Use a dedicated Rural-to-Metric transition coupling or BSP threaded adaptor to join the two systems safely.