DN75 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) — 50m Friction Loss Chart & Calculator
OD-measured 75 mm Metric PE100 (AS/NZS 4130, SDR13.6, 1250 kPa at 20°C). Mean ID of 63.8 mm delivers strong flow capacity (~2.5" effective bore) with high surge resilience for commercial farm mains and bushfire hydrant ring-mains.
- True Mean ID
- 63.8 mm
- Outside Dia (OD)
- 75 mm
- Wall Thickness
- 5.5 mm SDR13.6
- PN Rating (20°C)
- 1250 kPa 127 m max · 1050 kPa warn
- Derated (40°C)
- 925 kPa 74% AS/NZS 4130 (94 m)
- Safe Flow ≤1.5 m/s
- 288 L/min Hammer >460 L/min
- Fitting System
- External Full-Bore Metric Compression / Electrofusion
DN75 PE100 PN12.5 Friction Loss & Velocity Chart over 50 Metres
ID: 63.8 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (50m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.05 | 0.00 m | 0.0 kPa | 0.00 m | 0.0 psi | Safe (≤1.5 m/s) |
| 50 | 3,000 | 0.26 | 0.07 m | 0.7 kPa | 0.07 m | 0.1 psi | Safe (≤1.5 m/s) |
| 100 | 6,000 | 0.52 | 0.25 m | 2.5 kPa | 0.24 m | 0.4 psi | Safe (≤1.5 m/s) |
| 150 | 9,000 | 0.78 | 0.51 m | 5.0 kPa | 0.50 m | 0.7 psi | Safe (≤1.5 m/s) |
| 200 | 12,000 | 1.04 | 0.86 m | 8.4 kPa | 0.85 m | 1.2 psi | Safe (≤1.5 m/s) |
| 250 | 15,000 | 1.30 | 1.28 m | 12.5 kPa | 1.29 m | 1.8 psi | Safe (≤1.5 m/s) |
| 300 | 18,000 | 1.56 | 1.77 m | 17.4 kPa | 1.81 m | 2.5 psi | Caution (1.5–2.4 m/s) |
| 350 | 21,000 | 1.82 | 2.34 m | 22.9 kPa | 2.40 m | 3.3 psi | Caution (1.5–2.4 m/s) |
| 400 | 24,000 | 2.09 | 2.98 m | 29.2 kPa | 3.08 m | 4.2 psi | Caution (1.5–2.4 m/s) |
| 450 | 27,000 | 2.35 | 3.68 m | 36.1 kPa | 3.82 m | 5.2 psi | Caution (1.5–2.4 m/s) |
| 500 | 30,000 | 2.61 | 4.45 m | 43.7 kPa | 4.65 m | 6.3 psi | Water Hammer (>2.4 m/s) |
| 550 | 33,000 | 2.87 | 5.29 m | 51.9 kPa | 5.55 m | 7.5 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
Step up to DN90 PE100 PN12.5 & cut friction by 58.4%
Stepping up from DN75 PE100 PN12.5 (63.8 mm ID) to DN90 PE100 PN12.5 (76.6 mm ID) cuts pipe friction by 58.4% (saving 0.6 m / 6 kPa) and lowers velocity from 1.15 to 0.80 m/s.
Why DN75 PE100 wall thickness reduces true internal bore
Under AS/NZS 4130, DN75 Metric PE100 locks the outside diameter at 75 mm so external metric compression fittings seal universally across PN8–PN16. Higher PN classes grow inward (5.5 mm wall → 63.8 mm true ID), slightly increasing friction loss in exchange for 1250 kPa pressure safety.
DN75 PE100 PN12.5 vs Next Size Up (DN90 PE100 PN12.5) — 50 m Run
Length: 50 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive DN75 PE100 PN12.5 (50m) Pump & Friction Solver
Pre-loaded with 50 m of DN75 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) (63.8 mm ID) at 220 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsOD-measured 75 mm Metric PE100 (AS/NZS 4130, SDR13.6, 1250 kPa at 20°C). Mean ID of 63.8 mm delivers strong flow capacity (~2.5" effective bore) with high surge resilience for commercial farm mains and bushfire hydrant ring-mains.
2. Site Run & Hydraulic Conditions
Equivalent: 13,200 L/hr · 316,800 L/24h
3. Fittings & Valves (6)
ΣK = 9.60 · +27.1 m eq. pipe · 0.64 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.30 m (3.0 kPa · +12.8 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
Loss: 0.02 m (0.2 kPa · +0.8 m eq.)
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Loss: 0.10 m (1.0 kPa · +4.1 m eq.)
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Loss: 0.21 m (2.1 kPa · +8.9 m eq.)
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.5 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.15 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (229 kPa) is safely within DN75 PE100 PN12.5 working rating (1050 kPa warning / 1250 kPa max).
Total suction head is 1.80 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
No Direct Rural-vs-Metric Naming Trap
DN75 PE100 PN12.5 (63.8 mm true ID) does not share an ambiguous Rural/Metric nominal pair. Standard rural Class B poly tops out at 2" (50.9 mm ID), whereas DN63–DN90 Metric PE100 pipes offer larger high-pressure bores.
Step Up to DN90 PE100 PN12.5
Stepping up from DN75 PE100 PN12.5 (63.8 mm ID) to DN90 PE100 PN12.5 (76.6 mm ID) cuts pipe friction by 58.4% (saving 0.6 m / 6 kPa) and lowers velocity from 1.15 to 0.80 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 50 m DN75 PE100 PN12.5 system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
2" Trash / Transfer PumpActive Strong match: delivers 248.6 L/min at 23.8 m head (1.30 m/s) safely within pipe pressure limits. | Petrol | 248.6 L/min @ 23.8 m 233 kPa · 1.30 m/s | 28 m (275 kPa) | Recommended Match | $450–$980 AUD | |
Single-Impeller Fire Pump Strong match: delivers 363.5 L/min at 26.0 m head (1.90 m/s) safely within pipe pressure limits. | Petrol | 363.5 L/min @ 26.0 m 255 kPa · 1.90 m/s | 70 m (686 kPa) | Recommended Match | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Meets target flow at 327.0 L/min (25.2 m head), but note: near runout. | Petrol | 327.0 L/min @ 25.2 m 247 kPa · 1.70 m/s | 98 m (961 kPa) | Capable (Check Sizing) | $850–$1,650 AUD | |
240V Multistage Irrigation Pump Delivers 146.0 L/min (66% of 220 L/min target) at 22.5 m head. | 240V AC | 146.0 L/min @ 22.5 m 220 kPa · 0.76 m/s | 62 m (608 kPa) | Undersized Flow | $650–$1,450 AUD | |
240V Tank Jet Pump Delivers 60.3 L/min (27% of 220 L/min target) at 21.8 m head. | 240V AC | 60.3 L/min @ 21.8 m 214 kPa · 0.31 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD | |
Solar Bore Pump (24V/48V) Delivers 55.1 L/min (25% of 220 L/min target) at 21.8 m head. | Solar DC | 55.1 L/min @ 21.8 m 214 kPa · 0.29 m/s | 75 m (735 kPa) | Undersized Flow | $1,400–$3,200 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
Use AS/NZS 4130 Metric DN75 (75 mm OD) external compression or electrofusion fittings. Rural barbed insert fittings will NOT match this pipe's 63.8 mm bore.
- 1 × 2" High-Flow Petrol Trash & Dam Transfer Pump$450–$980 AUDInlet 50 mm / Outlet 50 mm · Shut-off 28 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.30 m
- 2 × Metric PE100 External Compression 90° ElbowK=1.50 · 0.10 m
- 1 × Metric PE100 External Compression JoinerK=0.25 · 0.02 m
- 1 × Spring-Loaded Brass / Stainless Check ValveK=3.20 · 0.21 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (DN75 PE100 PN12.5) and active pump category (2" Trash / Transfer Pump).
Australian Petrol Firefighting & Bulk Transfer Pumps
GX-style single-impeller, twin-impeller high-head, and 2" trash transfer pumps ready for rural delivery.
AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings
Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: DN75 PE100 PN12.5 over 50 Metres
What is the maximum safe flow rate for DN75 PE100 PN12.5 (63.8 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN75 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) (63.8 mm true internal diameter) safely carries up to 287.7 L/min (17,263 L/hr). Above 460.4 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 50m of DN75 PE100 PN12.5 have at 220 L/min?
Over a 50 m run at 220 L/min (velocity 1.15 m/s, 20°C water), DN75 PE100 PN12.5 loses 1.02 m of head (10 kPa / 1.4 PSI) via Darcy-Weisbach, compared with 1.02 m using Hazen-Williams (C=150).
What is the maximum pressure rating of DN75 PE100 PN12.5 in hot Australian summer conditions?
DN75 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) is rated to 1250 kPa maximum (127.5 m head; 1050 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 925 kPa (94.3 m head).
How much friction does stepping up from DN75 PE100 PN12.5 to DN90 PE100 PN12.5 save over 50m?
At 220 L/min over 50 m, stepping up from DN75 PE100 PN12.5 (63.8 mm ID) to DN90 PE100 PN12.5 (76.6 mm ID) cuts pipe friction loss by 58.4%—saving 0.59 m of head (6 kPa) and reducing water velocity from 1.15 m/s down to 0.80 m/s.