DN63 Metric PE100 PN8 (SDR21, Blue Stripe) — 300m Friction Loss Chart & Calculator
OD-measured 63 mm Metric PE100 (AS/NZS 4130, SDR21, 800 kPa at 20°C). Mean ID of 56.8 mm exceeds 2" Rural poly bore and delivers economical low-friction transfer for flat dam-to-tank runs and gravity stock mains.
- True Mean ID
- 56.8 mm
- Outside Dia (OD)
- 63 mm
- Wall Thickness
- 3 mm SDR21
- PN Rating (20°C)
- 800 kPa 82 m max · 680 kPa warn
- Derated (40°C)
- 592 kPa 74% AS/NZS 4130 (60 m)
- Safe Flow ≤1.5 m/s
- 228 L/min Hammer >365 L/min
- Fitting System
- External Full-Bore Metric Compression / Electrofusion
DN63 PE100 PN8 Friction Loss & Velocity Chart over 300 Metres
ID: 56.8 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (300m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.07 | 0.05 m | 0.4 kPa | 0.04 m | 0.1 psi | Safe (≤1.5 m/s) |
| 50 | 3,000 | 0.33 | 0.77 m | 7.5 kPa | 0.69 m | 1.1 psi | Safe (≤1.5 m/s) |
| 100 | 6,000 | 0.66 | 2.61 m | 25.6 kPa | 2.49 m | 3.7 psi | Safe (≤1.5 m/s) |
| 150 | 9,000 | 0.99 | 5.37 m | 52.7 kPa | 5.28 m | 7.6 psi | Safe (≤1.5 m/s) |
| 200 | 12,000 | 1.32 | 8.98 m | 88.1 kPa | 9.00 m | 12.8 psi | Safe (≤1.5 m/s) |
| 250 | 15,000 | 1.64 | 13.40 m | 131.4 kPa | 13.61 m | 19.1 psi | Caution (1.5–2.4 m/s) |
| 300 | 18,000 | 1.97 | 18.60 m | 182.4 kPa | 19.08 m | 26.4 psi | Caution (1.5–2.4 m/s) |
| 350 | 21,000 | 2.30 | 24.55 m | 240.8 kPa | 25.38 m | 34.9 psi | Caution (1.5–2.4 m/s) |
| 400 | 24,000 | 2.63 | 31.24 m | 306.4 kPa | 32.50 m | 44.4 psi | Water Hammer (>2.4 m/s) |
| 450 | 27,000 | 2.96 | 38.66 m | 379.2 kPa | 40.42 m | 55.0 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
Step up to DN75 PE100 PN8 & cut friction by 56.6%
Stepping up from DN63 PE100 PN8 (56.8 mm ID) to DN75 PE100 PN8 (67.6 mm ID) cuts pipe friction by 56.6% (saving 4.2 m / 41 kPa) and lowers velocity from 1.18 to 0.84 m/s.
Why DN63 PE100 wall thickness reduces true internal bore
Under AS/NZS 4130, DN63 Metric PE100 locks the outside diameter at 63 mm so external metric compression fittings seal universally across PN8–PN16. Higher PN classes grow inward (3 mm wall → 56.8 mm true ID), slightly increasing friction loss in exchange for 800 kPa pressure safety.
DN63 PE100 PN8 vs Next Size Up (DN75 PE100 PN8) — 300 m Run
Length: 300 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive DN63 PE100 PN8 (300m) Pump & Friction Solver
Pre-loaded with 300 m of DN63 Metric PE100 PN8 (SDR21, Blue Stripe) (56.8 mm ID) at 180 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsOD-measured 63 mm Metric PE100 (AS/NZS 4130, SDR21, 800 kPa at 20°C). Mean ID of 56.8 mm exceeds 2" Rural poly bore and delivers economical low-friction transfer for flat dam-to-tank runs and gravity stock mains.
2. Site Run & Hydraulic Conditions
Equivalent: 10,800 L/hr · 259,200 L/24h
3. Fittings & Valves (6)
ΣK = 9.60 · +24.1 m eq. pipe · 0.69 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.32 m (3.2 kPa · +11.4 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
Loss: 0.02 m (0.2 kPa · +0.7 m eq.)
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Loss: 0.11 m (1.1 kPa · +3.6 m eq.)
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Loss: 0.23 m (2.2 kPa · +8.0 m eq.)
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.5 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.18 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (292 kPa) is safely within DN63 PE100 PN8 working rating (680 kPa warning / 800 kPa max).
Total suction head is 1.82 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
No Direct Rural-vs-Metric Naming Trap
DN63 PE100 PN8 (56.8 mm true ID) does not share an ambiguous Rural/Metric nominal pair. Standard rural Class B poly tops out at 2" (50.9 mm ID), whereas DN63–DN90 Metric PE100 pipes offer larger high-pressure bores.
Step Up to DN75 PE100 PN8
Stepping up from DN63 PE100 PN8 (56.8 mm ID) to DN75 PE100 PN8 (67.6 mm ID) cuts pipe friction by 56.6% (saving 4.2 m / 41 kPa) and lowers velocity from 1.18 to 0.84 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 300 m DN63 PE100 PN8 system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
Single-Impeller Fire PumpActive Strong match: delivers 284.5 L/min at 40.3 m head (1.87 m/s) safely within pipe pressure limits. | Petrol | 284.5 L/min @ 40.3 m 395 kPa · 1.87 m/s | 70 m (686 kPa) | Recommended Match | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Delivers 288.1 L/min at 40.7 m head, but shut-off pressure (961 kPa) exceeds DN63 PE100 PN8 max rating (800 kPa). | Petrol | 288.1 L/min @ 40.7 m 400 kPa · 1.90 m/s | 98 m (961 kPa) Exceeds pipe max! | Overpressure Risk | $850–$1,650 AUD | |
240V Multistage Irrigation Pump Delivers 139.4 L/min (77% of 180 L/min target) at 26.8 m head. | 240V AC | 139.4 L/min @ 26.8 m 263 kPa · 0.92 m/s | 62 m (608 kPa) | Undersized Flow | $650–$1,450 AUD | |
2" Trash / Transfer Pump Delivers 132.1 L/min (73% of 180 L/min target) at 26.3 m head. | Petrol | 132.1 L/min @ 26.3 m 258 kPa · 0.87 m/s | 28 m (275 kPa) | Undersized Flow | $450–$980 AUD | |
240V Tank Jet Pump Delivers 58.4 L/min (32% of 180 L/min target) at 22.8 m head. | 240V AC | 58.4 L/min @ 22.8 m 223 kPa · 0.38 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD | |
Solar Bore Pump (24V/48V) Delivers 54.6 L/min (30% of 180 L/min target) at 22.7 m head. | Solar DC | 54.6 L/min @ 22.7 m 222 kPa · 0.36 m/s | 75 m (735 kPa) | Undersized Flow | $1,400–$3,200 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
+ 2 straight coil-to-coil joiners recommended to connect rolls.
Use AS/NZS 4130 Metric DN63 (63 mm OD) external compression or electrofusion fittings. Rural barbed insert fittings will NOT match this pipe's 56.8 mm bore.
- 1 × Single-Impeller Petrol Firefighting Pump (5.5–6.5 HP GX-Style)$550–$1,150 AUDInlet 40 mm / Outlet 40 mm · Shut-off 70 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.32 m
- 2 × Metric PE100 External Compression 90° ElbowK=1.50 · 0.11 m
- 1 × Metric PE100 External Compression JoinerK=0.25 · 0.02 m
- 1 × Spring-Loaded Brass / Stainless Check ValveK=3.20 · 0.23 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (DN63 PE100 PN8) and active pump category (Single-Impeller Fire Pump).
Australian Petrol Firefighting & Bulk Transfer Pumps
GX-style single-impeller, twin-impeller high-head, and 2" trash transfer pumps ready for rural delivery.
AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings
Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: DN63 PE100 PN8 over 300 Metres
What is the maximum safe flow rate for DN63 PE100 PN8 (56.8 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN63 Metric PE100 PN8 (SDR21, Blue Stripe) (56.8 mm true internal diameter) safely carries up to 228.0 L/min (13,683 L/hr). Above 364.9 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 300m of DN63 PE100 PN8 have at 180 L/min?
Over a 300 m run at 180 L/min (velocity 1.18 m/s, 20°C water), DN63 PE100 PN8 loses 7.44 m of head (73 kPa / 10.6 PSI) via Darcy-Weisbach, compared with 7.41 m using Hazen-Williams (C=150).
What is the maximum pressure rating of DN63 PE100 PN8 in hot Australian summer conditions?
DN63 Metric PE100 PN8 (SDR21, Blue Stripe) is rated to 800 kPa maximum (81.6 m head; 680 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 592 kPa (60.4 m head).
How much friction does stepping up from DN63 PE100 PN8 to DN75 PE100 PN8 save over 300m?
At 180 L/min over 300 m, stepping up from DN63 PE100 PN8 (56.8 mm ID) to DN75 PE100 PN8 (67.6 mm ID) cuts pipe friction loss by 56.6%—saving 4.21 m of head (41 kPa) and reducing water velocity from 1.18 m/s down to 0.84 m/s.