Skip to main content
Blue Stripe · Metric PE100 AS/NZS 4130 Measured by Outside Diameter (OD)

DN50 Metric PE100 PN8 (SDR21, Blue Stripe) — 50m Friction Loss Chart & Calculator

OD-measured 50 mm Metric PE100 (AS/NZS 4130, SDR21, 800 kPa at 20°C). Mean ID is 45.0 mm—still 5.9 mm narrower than 2" Rural Class B (50.9 mm ID). Uses external 50 mm metric compression or electrofusion fittings.

Switch Run Length (DN50 PE100 PN8)
Other DN50 Pressure Classes (50m)
True Mean ID
45 mm
Outside Dia (OD)
50 mm
Wall Thickness
2.4 mm SDR21
PN Rating (20°C)
800 kPa 82 m max · 680 kPa warn
Derated (40°C)
592 kPa 74% AS/NZS 4130 (60 m)
Safe Flow ≤1.5 m/s
143 L/min Hammer >229 L/min
Fitting System
External Full-Bore Metric Compression / Electrofusion
Zero-JS Engineering Reference Table · 20°C Water

DN50 PE100 PN8 Friction Loss & Velocity Chart over 50 Metres

ID: 45 mm · ε = 0.0015 mm · Hazen-Williams C = 150

Flow (L/min) Flow (L/hr) Velocity (m/s) Darcy Head (50m) Darcy Drop (kPa) Hazen-W C=150 (m) Drop (PSI) Safety Status
10 600 0.10 0.02 m 0.2 kPa 0.02 m 0.0 psi Safe (≤1.5 m/s)
30 1,800 0.31 0.16 m 1.6 kPa 0.14 m 0.2 psi Safe (≤1.5 m/s)
60 3,600 0.63 0.54 m 5.3 kPa 0.50 m 0.8 psi Safe (≤1.5 m/s)
90 5,400 0.94 1.10 m 10.8 kPa 1.06 m 1.6 psi Safe (≤1.5 m/s)
120 7,200 1.26 1.83 m 18.0 kPa 1.81 m 2.6 psi Safe (≤1.5 m/s)
150 9,000 1.57 2.73 m 26.8 kPa 2.74 m 3.9 psi Caution (1.5–2.4 m/s)
180 10,800 1.89 3.79 m 37.2 kPa 3.84 m 5.4 psi Caution (1.5–2.4 m/s)
210 12,600 2.20 5.00 m 49.0 kPa 5.11 m 7.1 psi Caution (1.5–2.4 m/s)
240 14,400 2.52 6.36 m 62.3 kPa 6.54 m 9.0 psi Water Hammer (>2.4 m/s)
270 16,200 2.83 7.86 m 77.1 kPa 8.13 m 11.2 psi Water Hammer (>2.4 m/s)

Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.

Blue Stripe · Metric PE100AS/NZS 4130 · OD-Measured

Interactive DN50 PE100 PN8 (50m) Pump & Friction Solver

Pre-loaded with 50 m of DN50 Metric PE100 PN8 (SDR21, Blue Stripe) (45 mm ID) at 110 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.

1. Pipe Standard & Size

44 AU Specs
Measured By
OD (Outer)
True Bore ID
45 mm
Outside OD
50 mm
Max @ 20°C
800 kPa

OD-measured 50 mm Metric PE100 (AS/NZS 4130, SDR21, 800 kPa at 20°C). Mean ID is 45.0 mm—still 5.9 mm narrower than 2" Rural Class B (50.9 mm ID). Uses external 50 mm metric compression or electrofusion fittings.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 6,600 L/hr · 158,400 L/24h

1 × 50 m coil
m
+98 kPa uphill
m
Total Suction: 1.80 m / 5.5 m max
m
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (6)

ΣK = 9.60 · +19.1 m eq. pipe · 0.65 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

Loss: 0.30 m (3.0 kPa · +9.0 m eq.)

1

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DDifferent fitting systemInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

0
Rural Barbed 90° ElbowK=1.9 · 85DDifferent fitting systemInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

0
Rural Barbed Tee (Branch)K=2.4 · 110DDifferent fitting systemInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12D

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

Loss: 0.02 m (0.2 kPa · +0.5 m eq.)

1
Metric Compression 90° ElbowK=0.75 · 32D

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

Loss: 0.10 m (1.0 kPa · +2.9 m eq.)

2
Metric Compression Tee (Branch)K=1.2 · 55D

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

Loss: 0.22 m (2.1 kPa · +6.3 m eq.)

1

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.4 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (DN50 PE100 PN8) and active pump category (240V Multistage Irrigation Pump).

240V Pressure SystemsAU Supplier

240V Rainwater Tank Jet & Multistage Irrigation Pumps

Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.

View Matching 240V Multistage Irrigation Pumps
AS/NZS 4130 PE100AU Supplier

AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings

Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.

Price 50m of DN50 PE100 PN8 + Compression Fittings

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Engineering Q&A: DN50 PE100 PN8 over 50 Metres

What is the maximum safe flow rate for DN50 PE100 PN8 (45 mm ID)?

For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN50 Metric PE100 PN8 (SDR21, Blue Stripe) (45 mm true internal diameter) safely carries up to 143.1 L/min (8,588 L/hr). Above 229.0 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.

How much friction head loss does 50m of DN50 PE100 PN8 have at 110 L/min?

Over a 50 m run at 110 L/min (velocity 1.15 m/s, 20°C water), DN50 PE100 PN8 loses 1.57 m of head (15 kPa / 2.2 PSI) via Darcy-Weisbach, compared with 1.54 m using Hazen-Williams (C=150).

What is the maximum pressure rating of DN50 PE100 PN8 in hot Australian summer conditions?

DN50 Metric PE100 PN8 (SDR21, Blue Stripe) is rated to 800 kPa maximum (81.6 m head; 680 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 592 kPa (60.4 m head).

How does DN50 PE100 PN8 compare to 2" Rural Class B in Australia?

2" Rural Class B is measured by Internal Diameter (50.9 mm ID) while DN50 PE100 PN8 is measured by Outside Diameter (50 mm OD, leaving 45 mm true ID). At 110 L/min over 50 m, the narrower Metric bore experiences 1.80× the friction loss (+0.7 m / +7 kPa), and Rural vs Metric fittings are physically incompatible.