DN50 Metric PE100 PN10 (SDR17, Blue Stripe) — 500m Friction Loss Chart & Calculator
OD-measured 50 mm Metric PE100 (AS/NZS 4130, SDR17, 1000 kPa at 20°C). Mean ID is 43.8 mm vs 50.9 mm in 2" Rural poly. Solid workhorse for acreage irrigation mains and medium-head farm transfers up to ~180 L/min.
- True Mean ID
- 43.8 mm
- Outside Dia (OD)
- 50 mm
- Wall Thickness
- 3 mm SDR17
- PN Rating (20°C)
- 1000 kPa 102 m max · 850 kPa warn
- Derated (40°C)
- 740 kPa 74% AS/NZS 4130 (75 m)
- Safe Flow ≤1.5 m/s
- 136 L/min Hammer >217 L/min
- Fitting System
- External Full-Bore Metric Compression / Electrofusion
DN50 PE100 PN10 Friction Loss & Velocity Chart over 500 Metres
ID: 43.8 mm · ε = 0.0015 mm · Hazen-Williams C = 150
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (500m) | Darcy Drop (kPa) | Hazen-W C=150 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.11 | 0.27 m | 2.6 kPa | 0.21 m | 0.4 psi | Safe (≤1.5 m/s) |
| 30 | 1,800 | 0.33 | 1.80 m | 17.7 kPa | 1.59 m | 2.6 psi | Safe (≤1.5 m/s) |
| 60 | 3,600 | 0.66 | 6.09 m | 59.8 kPa | 5.72 m | 8.7 psi | Safe (≤1.5 m/s) |
| 90 | 5,400 | 1.00 | 12.50 m | 122.6 kPa | 12.13 m | 17.8 psi | Safe (≤1.5 m/s) |
| 120 | 7,200 | 1.33 | 20.88 m | 204.7 kPa | 20.66 m | 29.7 psi | Safe (≤1.5 m/s) |
| 150 | 9,000 | 1.66 | 31.11 m | 305.1 kPa | 31.23 m | 44.3 psi | Caution (1.5–2.4 m/s) |
| 180 | 10,800 | 1.99 | 43.15 m | 423.1 kPa | 43.77 m | 61.4 psi | Caution (1.5–2.4 m/s) |
| 210 | 12,600 | 2.32 | 56.92 m | 558.2 kPa | 58.24 m | 81.0 psi | Caution (1.5–2.4 m/s) |
| 240 | 14,400 | 2.65 | 72.40 m | 710.0 kPa | 74.57 m | 103.0 psi | Water Hammer (>2.4 m/s) |
| 270 | 16,200 | 2.99 | 89.55 m | 878.2 kPa | 92.75 m | 127.4 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
Step up to DN63 PE100 PN10 & cut friction by 66.9%
Stepping up from DN50 PE100 PN10 (43.8 mm ID) to DN63 PE100 PN10 (55.2 mm ID) cuts pipe friction by 66.9% (saving 10.1 m / 99 kPa) and lowers velocity from 1.11 to 0.70 m/s.
Don’t confuse DN50 PE100 PN10 (43.8 mm ID) with 2" Rural Class B (50.9 mm ID)
DN50 PE100 PN10 (43.8 mm ID) has a 7.1 mm smaller bore than 2" Rural Class B (50.9 mm ID), causing 2.05× the pipe friction loss (+7.7 m / +76 kPa) and reducing 240V Multistage Irrigation Pump flow by 19.0 L/min (14.7%).
DN50 PE100 PN10 vs Next Size Up (DN63 PE100 PN10) — 500 m Run
Length: 500 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive DN50 PE100 PN10 (500m) Pump & Friction Solver
Pre-loaded with 500 m of DN50 Metric PE100 PN10 (SDR17, Blue Stripe) (43.8 mm ID) at 100 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsOD-measured 50 mm Metric PE100 (AS/NZS 4130, SDR17, 1000 kPa at 20°C). Mean ID is 43.8 mm vs 50.9 mm in 2" Rural poly. Solid workhorse for acreage irrigation mains and medium-head farm transfers up to ~180 L/min.
2. Site Run & Hydraulic Conditions
Equivalent: 6,000 L/hr · 144,000 L/24h
3. Fittings & Valves (6)
ΣK = 9.60 · +18.6 m eq. pipe · 0.60 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.28 m (2.8 kPa · +8.8 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
Loss: 0.02 m (0.2 kPa · +0.5 m eq.)
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Loss: 0.09 m (0.9 kPa · +2.8 m eq.)
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Loss: 0.20 m (2.0 kPa · +6.1 m eq.)
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.4 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.11 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (367 kPa) is safely within DN50 PE100 PN10 working rating (850 kPa warning / 1000 kPa max).
Total suction head is 1.78 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
2" Rural Class B vs. DN50 PE100 PN10
DN50 PE100 PN10 (43.8 mm ID) has a 7.1 mm smaller bore than 2" Rural Class B (50.9 mm ID), causing 2.05× the pipe friction loss (+7.7 m / +76 kPa) and reducing 240V Multistage Irrigation Pump flow by 19.0 L/min (14.9%).
Step Up to DN63 PE100 PN10
Stepping up from DN50 PE100 PN10 (43.8 mm ID) to DN63 PE100 PN10 (55.2 mm ID) cuts pipe friction by 66.9% (saving 10.1 m / 99 kPa) and lowers velocity from 1.11 to 0.70 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 500 m DN50 PE100 PN10 system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
240V Multistage Irrigation PumpActive Strong match: delivers 109.0 L/min at 40.0 m head (1.21 m/s) safely within pipe pressure limits. | 240V AC | 109.0 L/min @ 40.0 m 392 kPa · 1.21 m/s | 62 m (608 kPa) | Recommended Match | $650–$1,450 AUD | |
Single-Impeller Fire Pump Strong match: delivers 158.5 L/min at 57.6 m head (1.75 m/s) safely within pipe pressure limits. | Petrol | 158.5 L/min @ 57.6 m 564 kPa · 1.75 m/s | 70 m (686 kPa) | Recommended Match | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Strong match: delivers 188.4 L/min at 70.6 m head (2.08 m/s) safely within pipe pressure limits. | Petrol | 188.4 L/min @ 70.6 m 693 kPa · 2.08 m/s | 98 m (961 kPa) | Recommended Match | $850–$1,650 AUD | |
2" Trash / Transfer Pump Delivers 56.1 L/min (56% of 100 L/min target) at 27.3 m head. | Petrol | 56.1 L/min @ 27.3 m 268 kPa · 0.62 m/s | 28 m (275 kPa) | Undersized Flow | $450–$980 AUD | |
Solar Bore Pump (24V/48V) Delivers 52.3 L/min (52% of 100 L/min target) at 26.6 m head. | Solar DC | 52.3 L/min @ 26.6 m 261 kPa · 0.58 m/s | 75 m (735 kPa) | Undersized Flow | $1,400–$3,200 AUD | |
240V Tank Jet Pump Delivers 51.1 L/min (51% of 100 L/min target) at 26.4 m head. | 240V AC | 51.1 L/min @ 26.4 m 259 kPa · 0.57 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
+ 2 straight coil-to-coil joiners recommended to connect rolls.
Use AS/NZS 4130 Metric DN50 (50 mm OD) external compression or electrofusion fittings. Rural barbed insert fittings will NOT match this pipe's 43.8 mm bore.
- 1 × 240V Multistage Acreage Irrigation Pressure Pump$650–$1,450 AUDInlet 32 mm / Outlet 32 mm · Shut-off 62 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.28 m
- 2 × Metric PE100 External Compression 90° ElbowK=1.50 · 0.09 m
- 1 × Metric PE100 External Compression JoinerK=0.25 · 0.02 m
- 1 × Spring-Loaded Brass / Stainless Check ValveK=3.20 · 0.20 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (DN50 PE100 PN10) and active pump category (240V Multistage Irrigation Pump).
240V Rainwater Tank Jet & Multistage Irrigation Pumps
Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.
AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings
Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: DN50 PE100 PN10 over 500 Metres
What is the maximum safe flow rate for DN50 PE100 PN10 (43.8 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN50 Metric PE100 PN10 (SDR17, Blue Stripe) (43.8 mm true internal diameter) safely carries up to 135.6 L/min (8,136 L/hr). Above 217.0 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 500m of DN50 PE100 PN10 have at 100 L/min?
Over a 500 m run at 100 L/min (velocity 1.11 m/s, 20°C water), DN50 PE100 PN10 loses 15.08 m of head (148 kPa / 21.5 PSI) via Darcy-Weisbach, compared with 14.74 m using Hazen-Williams (C=150).
What is the maximum pressure rating of DN50 PE100 PN10 in hot Australian summer conditions?
DN50 Metric PE100 PN10 (SDR17, Blue Stripe) is rated to 1000 kPa maximum (102.0 m head; 850 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 740 kPa (75.5 m head).
How does DN50 PE100 PN10 compare to 2" Rural Class B in Australia?
2" Rural Class B is measured by Internal Diameter (50.9 mm ID) while DN50 PE100 PN10 is measured by Outside Diameter (50 mm OD, leaving 43.8 mm true ID). At 100 L/min over 500 m, the narrower Metric bore experiences 2.05× the friction loss (+7.7 m / +76 kPa), and Rural vs Metric fittings are physically incompatible.