Skip to main content
Blue Stripe · Metric PE100 AS/NZS 4130 Measured by Outside Diameter (OD)

DN25 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) — 500m Friction Loss Chart & Calculator

Classic Australian Rural-vs-Metric trap: DN25 PE100 PN12.5 is 25 mm OD with a 21.0 mm bore—NOT 1" (25.3 mm) ID. At the same flow rate, DN25 PN12.5 suffers ~2.4x the friction loss of 1" Rural Class B; step up to DN32 PE100 (27.0 mm ID) to match 1" Rural hydraulics.

Switch Run Length (DN25 PE100 PN12.5)
Other DN25 Pressure Classes (500m)
True Mean ID
21 mm
Outside Dia (OD)
25 mm
Wall Thickness
1.9 mm SDR13.6
PN Rating (20°C)
1250 kPa 127 m max · 1050 kPa warn
Derated (40°C)
925 kPa 74% AS/NZS 4130 (94 m)
Safe Flow ≤1.5 m/s
31 L/min Hammer >50 L/min
Fitting System
External Full-Bore Metric Compression / Electrofusion
Zero-JS Engineering Reference Table · 20°C Water

DN25 PE100 PN12.5 Friction Loss & Velocity Chart over 500 Metres

ID: 21 mm · ε = 0.0015 mm · Hazen-Williams C = 150

Flow (L/min) Flow (L/hr) Velocity (m/s) Darcy Head (500m) Darcy Drop (kPa) Hazen-W C=150 (m) Drop (PSI) Safety Status
10 600 0.48 8.70 m 85.3 kPa 7.44 m 12.4 psi Safe (≤1.5 m/s)
20 1,200 0.96 29.23 m 286.7 kPa 26.84 m 41.6 psi Safe (≤1.5 m/s)
30 1,800 1.44 59.81 m 586.5 kPa 56.88 m 85.1 psi Safe (≤1.5 m/s)
40 2,400 1.92 99.68 m 977.6 kPa 96.91 m 141.8 psi Caution (1.5–2.4 m/s)
50 3,000 2.41 148.40 m 1455.3 kPa >PN 146.50 m 211.1 psi Water Hammer (>2.4 m/s)
60 3,600 2.89 205.64 m 2016.6 kPa >PN 205.34 m 292.5 psi Water Hammer (>2.4 m/s)

Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.

Blue Stripe · Metric PE100AS/NZS 4130 · OD-Measured

Interactive DN25 PE100 PN12.5 (500m) Pump & Friction Solver

Pre-loaded with 500 m of DN25 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) (21 mm ID) at 25 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.

1. Pipe Standard & Size

44 AU Specs
Measured By
OD (Outer)
True Bore ID
21 mm
Outside OD
25 mm
Max @ 20°C
1250 kPa

Classic Australian Rural-vs-Metric trap: DN25 PE100 PN12.5 is 25 mm OD with a 21.0 mm bore—NOT 1" (25.3 mm) ID. At the same flow rate, DN25 PN12.5 suffers ~2.4x the friction loss of 1" Rural Class B; step up to DN32 PE100 (27.0 mm ID) to match 1" Rural hydraulics.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 1,500 L/hr · 36,000 L/24h

2 × 200 m coils + 1 × 100 m coil
m
+98 kPa uphill
m
Total Suction: 1.83 m / 5.5 m max
m
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (6)

ΣK = 9.60 · +8.9 m eq. pipe · 0.71 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

Loss: 0.33 m (3.3 kPa · +4.2 m eq.)

1

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DDifferent fitting systemInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

0
Rural Barbed 90° ElbowK=1.9 · 85DDifferent fitting systemInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

0
Rural Barbed Tee (Branch)K=2.4 · 110DDifferent fitting systemInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12D

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

Loss: 0.02 m (0.2 kPa · +0.3 m eq.)

1
Metric Compression 90° ElbowK=0.75 · 32D

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

Loss: 0.11 m (1.1 kPa · +1.3 m eq.)

2
Metric Compression Tee (Branch)K=1.2 · 55D

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

Loss: 0.24 m (2.3 kPa · +2.9 m eq.)

1

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.2 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (DN25 PE100 PN12.5) and active pump category (Single-Impeller Fire Pump).

AU Fire & TransferAU Supplier

Australian Petrol Firefighting & Bulk Transfer Pumps

GX-style single-impeller, twin-impeller high-head, and 2" trash transfer pumps ready for rural delivery.

View Matching Single-Impeller Fire Pumps
AS/NZS 4130 PE100AU Supplier

AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings

Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.

Price 500m of DN25 PE100 PN12.5 + Compression Fittings

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Engineering Q&A: DN25 PE100 PN12.5 over 500 Metres

What is the maximum safe flow rate for DN25 PE100 PN12.5 (21 mm ID)?

For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, DN25 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) (21 mm true internal diameter) safely carries up to 31.2 L/min (1,870 L/hr). Above 49.9 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.

How much friction head loss does 500m of DN25 PE100 PN12.5 have at 25 L/min?

Over a 500 m run at 25 L/min (velocity 1.20 m/s, 20°C water), DN25 PE100 PN12.5 loses 43.32 m of head (425 kPa / 61.6 PSI) via Darcy-Weisbach, compared with 40.58 m using Hazen-Williams (C=150).

What is the maximum pressure rating of DN25 PE100 PN12.5 in hot Australian summer conditions?

DN25 Metric PE100 PN12.5 (SDR13.6, Blue Stripe) is rated to 1250 kPa maximum (127.5 m head; 1050 kPa continuous working caution) at 20°C under AS/NZS 4130. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 925 kPa (94.3 m head).

How does DN25 PE100 PN12.5 compare to 1" Rural Class B in Australia?

1" Rural Class B is measured by Internal Diameter (25.3 mm ID) while DN25 PE100 PN12.5 is measured by Outside Diameter (25 mm OD, leaving 21 mm true ID). At 25 L/min over 500 m, the narrower Metric bore experiences 2.43× the friction loss (+25.5 m / +250 kPa), and Rural vs Metric fittings are physically incompatible.