2" (50 mm) Heavy-Duty PVC Helical Suction & Delivery Hose — 50m Friction Loss Chart & Calculator
ID-measured 50 mm rigid-helix PVC suction and delivery hose designed to resist vacuum collapse on dam/tank pump suction lines as well as high-flow 2" trash pump discharge. Keep suction lift + friction loss below 5.5 m and delivery pressure below 600 kPa continuous / 800 kPa max.
- True Mean ID
- 50 mm
- Outside Dia (OD)
- 58 mm
- Wall Thickness
- 4 mm
- PN Rating (20°C)
- 800 kPa 82 m max · 600 kPa warn
- Derated (40°C)
- 800 kPa Reinforced hose
- Safe Flow ≤1.5 m/s
- 177 L/min Hammer >283 L/min
- Fitting System
- Camlock, Storz, BIC or BSP Hose Tail
2" Suction/Delivery Hose Friction Loss & Velocity Chart over 50 Metres
ID: 50 mm · ε = 0.005 mm · Hazen-Williams C = 140
| Flow (L/min) | Flow (L/hr) | Velocity (m/s) | Darcy Head (50m) | Darcy Drop (kPa) | Hazen-W C=140 (m) | Drop (PSI) | Safety Status |
|---|---|---|---|---|---|---|---|
| 10 | 600 | 0.08 | 0.01 m | 0.1 kPa | 0.01 m | 0.0 psi | Safe (≤1.5 m/s) |
| 30 | 1,800 | 0.25 | 0.10 m | 0.9 kPa | 0.09 m | 0.1 psi | Safe (≤1.5 m/s) |
| 60 | 3,600 | 0.51 | 0.33 m | 3.2 kPa | 0.34 m | 0.5 psi | Safe (≤1.5 m/s) |
| 90 | 5,400 | 0.76 | 0.67 m | 6.6 kPa | 0.72 m | 1.0 psi | Safe (≤1.5 m/s) |
| 120 | 7,200 | 1.02 | 1.12 m | 11.0 kPa | 1.23 m | 1.6 psi | Safe (≤1.5 m/s) |
| 150 | 9,000 | 1.27 | 1.67 m | 16.4 kPa | 1.86 m | 2.4 psi | Safe (≤1.5 m/s) |
| 180 | 10,800 | 1.53 | 2.32 m | 22.8 kPa | 2.61 m | 3.3 psi | Caution (1.5–2.4 m/s) |
| 210 | 12,600 | 1.78 | 3.07 m | 30.1 kPa | 3.47 m | 4.4 psi | Caution (1.5–2.4 m/s) |
| 240 | 14,400 | 2.04 | 3.91 m | 38.3 kPa | 4.45 m | 5.6 psi | Caution (1.5–2.4 m/s) |
| 270 | 16,200 | 2.29 | 4.84 m | 47.5 kPa | 5.53 m | 6.9 psi | Caution (1.5–2.4 m/s) |
| 300 | 18,000 | 2.55 | 5.86 m | 57.5 kPa | 6.72 m | 8.3 psi | Water Hammer (>2.4 m/s) |
| 330 | 19,800 | 2.80 | 6.97 m | 68.4 kPa | 8.02 m | 9.9 psi | Water Hammer (>2.4 m/s) |
Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.
2" Suction/Delivery Hose is the largest standard diameter in this pipe family
With a 50 mm true internal bore, 2" Suction/Delivery Hose safely moves up to 177 L/min at ≤1.5 m/s velocity. If your system demands even greater capacity or higher pressure rating than 800 kPa, consider stepping into Metric PE100 DN63–DN90 PN12.5/PN16 mains.
High-flow delivery & coupling discipline for 2" Suction/Delivery Hose
2" (50 mm) Heavy-Duty PVC Helical Suction & Delivery Hose carries a 50 mm true bore with wall roughness ε = 0.005 mm (Hazen-Williams C = 140). Keep delivery hoses unkinked and ensure suction lines never exceed 5.5 m combined static lift + foot-valve friction.
2" Suction/Delivery Hose System Head Curve — 50 m Run
Length: 50 m · Static Rise: 10 m · Outlet: 100 kPa · Darcy-Weisbach (20°C)
Interactive 2" Suction/Delivery Hose (50m) Pump & Friction Solver
Pre-loaded with 50 m of 2" (50 mm) Heavy-Duty PVC Helical Suction & Delivery Hose (50 mm ID) at 140 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.
1. Pipe Standard & Size
44 AU SpecsID-measured 50 mm rigid-helix PVC suction and delivery hose designed to resist vacuum collapse on dam/tank pump suction lines as well as high-flow 2" trash pump discharge. Keep suction lift + friction loss below 5.5 m and delivery pressure below 600 kPa continuous / 800 kPa max.
2. Site Run & Hydraulic Conditions
Equivalent: 8,400 L/hr · 201,600 L/24h
3. Fittings & Valves (2)
ΣK = 4.65 · +10.4 m eq. pipe · 0.33 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Loss: 0.32 m (3.2 kPa · +10.0 m eq.)
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.4 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 1.19 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (231 kPa) is safely within 2" Suction/Delivery Hose working rating (600 kPa warning / 800 kPa max).
Total suction head is 1.82 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
No Direct Rural-vs-Metric Naming Trap
2" Suction/Delivery Hose (50 mm true ID) does not share an ambiguous Rural/Metric nominal pair. Standard rural Class B poly tops out at 2" (50.9 mm ID), whereas DN63–DN90 Metric PE100 pipes offer larger high-pressure bores.
Largest Standard Bore in This Pipe Family
2" Suction/Delivery Hose (50 mm ID) is the largest standard coil size in its pipe family. For higher flows or lower friction, consider switching to larger Metric PE100 (DN63–DN90).
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 50 m 2" Suction/Delivery Hose system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
240V Multistage Irrigation PumpActive Strong match: delivers 144.3 L/min at 23.6 m head (1.22 m/s) safely within pipe pressure limits. | 240V AC | 144.3 L/min @ 23.6 m 232 kPa · 1.22 m/s | 62 m (608 kPa) | Recommended Match | $650–$1,450 AUD | |
2" Trash / Transfer Pump Strong match: delivers 196.7 L/min at 25.1 m head (1.67 m/s) safely within pipe pressure limits. | Petrol | 196.7 L/min @ 25.1 m 246 kPa · 1.67 m/s | 28 m (275 kPa) | Recommended Match | $450–$980 AUD | |
Single-Impeller Fire Pump Meets target flow at 339.3 L/min (31.0 m head), but note: high velocity (2.88 m/s). | Petrol | 339.3 L/min @ 31.0 m 304 kPa · 2.88 m/s | 70 m (686 kPa) | Capable (Check Sizing) | $550–$1,150 AUD | |
Twin-Impeller Fire Pump Delivers 315.5 L/min at 29.8 m head, but shut-off pressure (961 kPa) exceeds 2" Suction/Delivery Hose max rating (800 kPa). | Petrol | 315.5 L/min @ 29.8 m 292 kPa · 2.68 m/s | 98 m (961 kPa) Exceeds pipe max! | Overpressure Risk | $850–$1,650 AUD | |
240V Tank Jet Pump Delivers 59.8 L/min (43% of 140 L/min target) at 22.1 m head. | 240V AC | 59.8 L/min @ 22.1 m 217 kPa · 0.51 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD | |
Solar Bore Pump (24V/48V) Delivers 55.0 L/min (39% of 140 L/min target) at 22.0 m head. | Solar DC | 55.0 L/min @ 22.0 m 216 kPa · 0.47 m/s | 75 m (735 kPa) | Undersized Flow | $1,400–$3,200 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
+ 1 straight coil-to-coil joiner recommended to connect rolls.
Use 2" (50 mm ID) Australian Camlock, Storz, BIC, or BSP hose-tail couplings secured with heavy-duty T-bolt or Band-It clamps.
- 1 × 240V Multistage Acreage Irrigation Pressure Pump$650–$1,450 AUDInlet 32 mm / Outlet 32 mm · Shut-off 62 m
- 1 × Suction Foot Valve & Strainer BasketK=4.50 · 0.32 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (2" Suction/Delivery Hose) and active pump category (240V Multistage Irrigation Pump).
240V Rainwater Tank Jet & Multistage Irrigation Pumps
Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.
Heavy-Duty Suction Hose, Fire Reels & Non-Return Foot Valves
Vacuum-rated 2" helical suction kits and 1"–1.5" layflat hoses with Australian Camlock and Storz fittings.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
Engineering Q&A: 2" Suction/Delivery Hose over 50 Metres
What is the maximum safe flow rate for 2" Suction/Delivery Hose (50 mm ID)?
For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, 2" (50 mm) Heavy-Duty PVC Helical Suction & Delivery Hose (50 mm true internal diameter) safely carries up to 176.7 L/min (10,603 L/hr). Above 282.7 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.
How much friction head loss does 50m of 2" Suction/Delivery Hose have at 140 L/min?
Over a 50 m run at 140 L/min (velocity 1.19 m/s, 20°C water), 2" Suction/Delivery Hose loses 1.48 m of head (14 kPa / 2.1 PSI) via Darcy-Weisbach, compared with 1.64 m using Hazen-Williams (C=140).
What is the maximum pressure rating of 2" Suction/Delivery Hose in hot Australian summer conditions?
2" (50 mm) Heavy-Duty PVC Helical Suction & Delivery Hose is rated to 600 kPa continuous working pressure and 800 kPa maximum (81.6 m head) using reinforced hose construction (not PE temperature-derated under AS/NZS 4130, though always inspect couplings and avoid kinks).