Skip to main content
Red Line · Rural PN9 Heavy Wall AS 2698.2 Measured by Internal Diameter (ID)

1" Rural Poly Pipe Red Line (PN9 Heavy Wall) — 300m Friction Loss Chart & Calculator

Heavy-wall ID-measured 1" rural poly (AS 2698.2 Red Stripe, PN9 / 900 kPa at 20°C). Retains the full 25.3 mm rural internal bore while adding wall thickness (2.2 mm, OD 29.7 mm) for rougher trenches, higher head, and improved barb retention. Still incompatible with metric DN25 fittings.

Switch Run Length (1" Rural Red Line)
Other 1" Pressure Classes (300m)
True Mean ID
25.3 mm
Outside Dia (OD)
29.7 mm
Wall Thickness
2.2 mm
PN Rating (20°C)
900 kPa 92 m max · 800 kPa warn
Derated (40°C)
666 kPa 74% AS/NZS 4130 (68 m)
Safe Flow ≤1.5 m/s
45 L/min Hammer >72 L/min
Fitting System
Rural Barbed Insert or Rural Compression
Zero-JS Engineering Reference Table · 20°C Water

1" Rural Red Line Friction Loss & Velocity Chart over 300 Metres

ID: 25.3 mm · ε = 0.0015 mm · Hazen-Williams C = 150

Flow (L/min) Flow (L/hr) Velocity (m/s) Darcy Head (300m) Darcy Drop (kPa) Hazen-W C=150 (m) Drop (PSI) Safety Status
10 600 0.33 2.16 m 21.2 kPa 1.80 m 3.1 psi Safe (≤1.5 m/s)
20 1,200 0.66 7.22 m 70.8 kPa 6.50 m 10.3 psi Safe (≤1.5 m/s)
30 1,800 0.99 14.74 m 144.6 kPa 13.78 m 21.0 psi Safe (≤1.5 m/s)
40 2,400 1.33 24.53 m 240.5 kPa 23.47 m 34.9 psi Safe (≤1.5 m/s)
50 3,000 1.66 36.46 m 357.5 kPa 35.48 m 51.9 psi Caution (1.5–2.4 m/s)
60 3,600 1.99 50.46 m 494.8 kPa 49.73 m 71.8 psi Caution (1.5–2.4 m/s)
70 4,200 2.32 66.46 m 651.7 kPa 66.16 m 94.5 psi Caution (1.5–2.4 m/s)
80 4,800 2.65 84.42 m 827.8 kPa 84.72 m 120.1 psi Water Hammer (>2.4 m/s)
90 5,400 2.98 104.29 m 1022.7 kPa >PN 105.37 m 148.3 psi Water Hammer (>2.4 m/s)

Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.

Red Line · Rural PN9AS 2698.2 · ID-Measured

Interactive 1" Rural Red Line (300m) Pump & Friction Solver

Pre-loaded with 300 m of 1" Rural Poly Pipe Red Line (PN9 Heavy Wall) (25.3 mm ID) at 35 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.

1. Pipe Standard & Size

44 AU Specs
Measured By
ID (Bore)
True Bore ID
25.3 mm
Outside OD
29.7 mm
Max @ 20°C
900 kPa

Heavy-wall ID-measured 1" rural poly (AS 2698.2 Red Stripe, PN9 / 900 kPa at 20°C). Retains the full 25.3 mm rural internal bore while adding wall thickness (2.2 mm, OD 29.7 mm) for rougher trenches, higher head, and improved barb retention. Still incompatible with metric DN25 fittings.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 2,100 L/hr · 50,400 L/24h

1 × 200 m coil + 1 × 100 m coil
m
+98 kPa uphill
m
Total Suction: 1.81 m / 5.5 m max
m
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (5)

ΣK = 9.65 · +11.0 m eq. pipe · 0.66 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

Loss: 0.31 m (3.0 kPa · +5.1 m eq.)

1

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

Loss: 0.08 m (0.8 kPa · +1.4 m eq.)

1
Rural Barbed 90° ElbowK=1.9 · 85DInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

Loss: 0.26 m (2.6 kPa · +4.3 m eq.)

2
Rural Barbed Tee (Branch)K=2.4 · 110DInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12D

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

0
Metric Compression 90° ElbowK=0.75 · 32D

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

0
Metric Compression Tee (Branch)K=1.2 · 55D

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

0

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.2 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (1" Rural Red Line) and active pump category (Solar Bore Pump (24V/48V)).

Solar Bore SpecialistQuote Partner

Off-Grid Solar Bore Kits Sized to Your Total Dynamic Head

Compare 24V/48V brushless submersible kits matched to your calculated head, flow rate, and poly drop-pipe.

Get Matched Solar Bore Pump Packages
AS 2698.2 Rural PolyAU Supplier

AS 2698.2 Rural Poly Pipe & Matched Rural Fittings

Avoid the metric fitting trap—order ID-measured Green Stripe Class B or Red Line PN9 coils with rural compression or barbed joiners.

Price 300m of 1" Rural Red Line + Barbed Fittings

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Engineering Q&A: 1" Rural Red Line over 300 Metres

What is the maximum safe flow rate for 1" Rural Red Line (25.3 mm ID)?

For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, 1" Rural Poly Pipe Red Line (PN9 Heavy Wall) (25.3 mm true internal diameter) safely carries up to 45.2 L/min (2,715 L/hr). Above 72.4 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.

How much friction head loss does 300m of 1" Rural Red Line have at 35 L/min?

Over a 300 m run at 35 L/min (velocity 1.16 m/s, 20°C water), 1" Rural Red Line loses 19.36 m of head (190 kPa / 27.5 PSI) via Darcy-Weisbach, compared with 18.33 m using Hazen-Williams (C=150).

What is the maximum pressure rating of 1" Rural Red Line in hot Australian summer conditions?

1" Rural Poly Pipe Red Line (PN9 Heavy Wall) is rated to 900 kPa maximum (91.8 m head; 800 kPa continuous working caution) at 20°C under AS 2698.2. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 666 kPa (67.9 m head).

How does 1" Rural Red Line compare to DN25 PE100 PN12.5 in Australia?

1" Rural Red Line is measured by Internal Diameter (25.3 mm ID) while DN25 PE100 PN12.5 is measured by Outside Diameter (25 mm OD, leaving 21 mm true ID). At 35 L/min over 300 m, the narrower Metric bore experiences 2.44× the friction loss (+27.8 m / +273 kPa), and Rural vs Metric fittings are physically incompatible.