Skip to main content
Red Line · Rural PN9 Heavy Wall AS 2698.2 Measured by Internal Diameter (ID)

1 1/4" Rural Poly Pipe Red Line (PN9 Heavy Wall) — 100m Friction Loss Chart & Calculator

Heavy-wall ID-measured 1 1/4" rural poly (AS 2698.2 Red Stripe, PN9 / 900 kPa at 20°C). Holds the full 31.7 mm bore (vs 27.0 mm in DN32 PE100 PN12.5) with a 2.6 mm wall (OD 36.9 mm) suited to stony rural runs and higher-pressure bore delivery.

Switch Run Length (1 1/4" Rural Red Line)
Other 1 1/4" Pressure Classes (100m)
True Mean ID
31.7 mm
Outside Dia (OD)
36.9 mm
Wall Thickness
2.6 mm
PN Rating (20°C)
900 kPa 92 m max · 800 kPa warn
Derated (40°C)
666 kPa 74% AS/NZS 4130 (68 m)
Safe Flow ≤1.5 m/s
71 L/min Hammer >114 L/min
Fitting System
Rural Barbed Insert or Rural Compression
Zero-JS Engineering Reference Table · 20°C Water

1 1/4" Rural Red Line Friction Loss & Velocity Chart over 100 Metres

ID: 31.7 mm · ε = 0.0015 mm · Hazen-Williams C = 150

Flow (L/min) Flow (L/hr) Velocity (m/s) Darcy Head (100m) Darcy Drop (kPa) Hazen-W C=150 (m) Drop (PSI) Safety Status
10 600 0.21 0.25 m 2.4 kPa 0.20 m 0.4 psi Safe (≤1.5 m/s)
20 1,200 0.42 0.82 m 8.1 kPa 0.72 m 1.2 psi Safe (≤1.5 m/s)
40 2,400 0.84 2.78 m 27.3 kPa 2.61 m 4.0 psi Safe (≤1.5 m/s)
60 3,600 1.27 5.71 m 56.0 kPa 5.53 m 8.1 psi Safe (≤1.5 m/s)
80 4,800 1.69 9.53 m 93.5 kPa 9.42 m 13.6 psi Caution (1.5–2.4 m/s)
100 6,000 2.11 14.21 m 139.3 kPa 14.23 m 20.2 psi Caution (1.5–2.4 m/s)
120 7,200 2.53 19.70 m 193.2 kPa 19.95 m 28.0 psi Water Hammer (>2.4 m/s)
140 8,400 2.96 26.00 m 255.0 kPa 26.54 m 37.0 psi Water Hammer (>2.4 m/s)

Notes: Friction figures represent straight-pipe major losses only (20°C clean water, Colebrook-White Darcy-Weisbach). Add static elevation, suction lift, outlet pressure, and minor fitting losses (barbed elbows/joiners, foot valve, check valves) using the live calculator below.

Red Line · Rural PN9AS 2698.2 · ID-Measured

Interactive 1 1/4" Rural Red Line (100m) Pump & Friction Solver

Pre-loaded with 100 m of 1 1/4" Rural Poly Pipe Red Line (PN9 Heavy Wall) (31.7 mm ID) at 50 L/min. Adjust elevation, fittings, water temperature, and pump archetype below.

1. Pipe Standard & Size

44 AU Specs
Measured By
ID (Bore)
True Bore ID
31.7 mm
Outside OD
36.9 mm
Max @ 20°C
900 kPa

Heavy-wall ID-measured 1 1/4" rural poly (AS 2698.2 Red Stripe, PN9 / 900 kPa at 20°C). Holds the full 31.7 mm bore (vs 27.0 mm in DN32 PE100 PN12.5) with a 2.6 mm wall (OD 36.9 mm) suited to stony rural runs and higher-pressure bore delivery.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 3,000 L/hr · 72,000 L/24h

1 × 100 m coil
m
+98 kPa uphill
m
Total Suction: 1.76 m / 5.5 m max
m
m
KPA
100% nominal PN rating (≤ 20°C)
°C

3. Fittings & Valves (5)

ΣK = 9.65 · +13.7 m eq. pipe · 0.55 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

Loss: 0.26 m (2.5 kPa · +6.3 m eq.)

1

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

Loss: 0.07 m (0.7 kPa · +1.7 m eq.)

1
Rural Barbed 90° ElbowK=1.9 · 85DInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

Loss: 0.22 m (2.1 kPa · +5.4 m eq.)

2
Rural Barbed Tee (Branch)K=2.4 · 110DInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12D

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

0
Metric Compression 90° ElbowK=0.75 · 32D

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

0
Metric Compression Tee (Branch)K=1.2 · 55D

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

0

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.3 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (1 1/4" Rural Red Line) and active pump category (240V Tank Jet Pump).

240V Pressure SystemsAU Supplier

240V Rainwater Tank Jet & Multistage Irrigation Pumps

Automatic constant-pressure pumps sized for Australian rural homes, sheds, and acreage sprinkler zones.

View Matching 240V Tank Jet Pumps
AS 2698.2 Rural PolyAU Supplier

AS 2698.2 Rural Poly Pipe & Matched Rural Fittings

Avoid the metric fitting trap—order ID-measured Green Stripe Class B or Red Line PN9 coils with rural compression or barbed joiners.

Price 100m of 1 1/4" Rural Red Line + Barbed Fittings

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Engineering Q&A: 1 1/4" Rural Red Line over 100 Metres

What is the maximum safe flow rate for 1 1/4" Rural Red Line (31.7 mm ID)?

For continuous farm and irrigation service at or below the 1.5 m/s velocity guideline, 1 1/4" Rural Poly Pipe Red Line (PN9 Heavy Wall) (31.7 mm true internal diameter) safely carries up to 71.0 L/min (4,262 L/hr). Above 113.7 L/min (2.4 m/s), flow enters the water-hammer risk zone where rapid valve closure can spike pressure sharply.

How much friction head loss does 100m of 1 1/4" Rural Red Line have at 50 L/min?

Over a 100 m run at 50 L/min (velocity 1.06 m/s, 20°C water), 1 1/4" Rural Red Line loses 4.13 m of head (41 kPa / 5.9 PSI) via Darcy-Weisbach, compared with 3.94 m using Hazen-Williams (C=150).

What is the maximum pressure rating of 1 1/4" Rural Red Line in hot Australian summer conditions?

1 1/4" Rural Poly Pipe Red Line (PN9 Heavy Wall) is rated to 900 kPa maximum (91.8 m head; 800 kPa continuous working caution) at 20°C under AS 2698.2. Because PE poly softens in Australian summer heat, AS/NZS 4130 / PIPA POP013 applies a 74% temperature derating factor at 40°C, reducing maximum working pressure to 666 kPa (67.9 m head).

How does 1 1/4" Rural Red Line compare to DN32 PE100 PN12.5 in Australia?

1 1/4" Rural Red Line is measured by Internal Diameter (31.7 mm ID) while DN32 PE100 PN12.5 is measured by Outside Diameter (32 mm OD, leaving 27 mm true ID). At 50 L/min over 100 m, the narrower Metric bore experiences 2.15× the friction loss (+4.8 m / +47 kPa), and Rural vs Metric fittings are physically incompatible.