Solar Bore Submersible Pump & Poly Riser Sizing Calculator (AU)
Calculate daily bore yield (L/day at 5.5 peak sun hours), drop-pipe pressure class, and paddock delivery friction.
Solar Bore Submersible Sizing
Calculate daily bore yield (L/day at 5.5 peak sun hours), drop-pipe pressure class, and paddock delivery friction.
1. Pipe Standard & Size
44 AU SpecsOD-measured 32 mm Metric PE100 (AS/NZS 4130, SDR13.6, 1250 kPa at 20°C). Mean ID is 27.0 mm—closer hydraulically to 1" Rural (25.3 mm ID) than to 1 1/4" Rural (31.7 mm ID). Widely used for solar bore risers and high-pressure rural house mains.
2. Site Run & Hydraulic Conditions
Equivalent: 1,800 L/hr · 43,200 L/24h
Sun-exposed black poly across Australian paddocks regularly exceeds 40°C. At 25°C, DN32 PE100 PN12.5 drops from 1250 kPa to 1163 kPa max (118.5 m head).
3. Fittings & Valves (7)
ΣK = 6.10 · +7.2 m eq. pipe · 0.24 m loss
Suction Intake & Strainer
Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.
Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.
Delivery Fittings & Non-Return Valves
Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.
Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.
High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.
Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.
Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.
Loss: 0.02 m (0.2 kPa · +0.6 m eq.)
External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.
Loss: 0.09 m (0.9 kPa · +2.6 m eq.)
Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).
Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.
Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.
Loss: 0.12 m (1.2 kPa · +3.8 m eq.)
Isolation Valves
Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.
True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.
Loss: 0.01 m (0.1 kPa · +0.2 m eq.)
Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.
Water velocity is 0.87 m/s, safely within the <= 1.5 m/s design range for low friction and minimal water hammer.
Total dynamic pressure (517 kPa) is safely within DN32 PE100 PN12.5 working rating (977 kPa warning / 1163 kPa max (derated to 93% at 25°C under AS/NZS 4130)).
Total suction head is 0.00 m, safely below the 5.5 m cavitation & priming threshold.
Interactive System Curve vs. Australian Pump Curves
Click any pump chip below to overlay its H-Q curve, check shut-off pressure against pipe PN rating, and locate the exact duty point.
1 1/4" Rural Class B vs. DN32 PE100 PN12.5
DN32 PE100 PN12.5 (27 mm ID) has a 4.7 mm smaller bore than 1 1/4" Rural Class B (31.7 mm ID), causing 2.15× the pipe friction loss (+5.6 m / +55 kPa) and reducing Solar Bore Pump (24V/48V) flow by 4.1 L/min (11.4%).
Step Up to DN40 PE100 PN12.5
Stepping up from DN32 PE100 PN12.5 (27 mm ID) to DN40 PE100 PN12.5 (33.8 mm ID) cuts pipe friction by 65.7% (saving 6.9 m / 68 kPa) and lowers velocity from 0.87 to 0.56 m/s.
Recommended Australian Pump Archetypes (Ranked for Your System)
Exact bisection intersection between each pump's H-Q curve and your 300 m DN32 PE100 PN12.5 system curve. Click any pump to inspect on the chart and verify dead-head pipe safety.
| Pump Archetype | Power | Solved Operating Duty Point | Shut-Off Head | Status | Est. AU Price | Compare |
|---|---|---|---|---|---|---|
Solar Bore Pump (24V/48V)Active Strong match: delivers 31.7 L/min at 53.9 m head (0.92 m/s) safely within pipe pressure limits. | Solar DC | 31.7 L/min @ 53.9 m 528 kPa · 0.92 m/s | 75 m (735 kPa) | Recommended Match | $1,400–$3,200 AUD | |
240V Multistage Irrigation Pump Strong match: delivers 36.7 L/min at 57.4 m head (1.07 m/s) safely within pipe pressure limits. | 240V AC | 36.7 L/min @ 57.4 m 563 kPa · 1.07 m/s | 62 m (608 kPa) | Recommended Match | $650–$1,450 AUD | |
Twin-Impeller Fire Pump Strong match: delivers 70.8 L/min at 91.8 m head (2.06 m/s) safely within pipe pressure limits. | Petrol | 70.8 L/min @ 91.8 m 900 kPa · 2.06 m/s | 98 m (961 kPa) | Recommended Match | $850–$1,650 AUD | |
Single-Impeller Fire Pump Meets target flow at 48.3 L/min (67.1 m head), but note: very low flow on pump curve. | Petrol | 48.3 L/min @ 67.1 m 658 kPa · 1.41 m/s | 70 m (686 kPa) | Capable (Check Sizing) | $550–$1,150 AUD | |
240V Tank Jet Pump Delivers 9.0 L/min (30% of 30 L/min target) at 43.3 m head. | 240V AC | 9.0 L/min @ 43.3 m 425 kPa · 0.26 m/s | 46 m (451 kPa) | Undersized Flow | $380–$780 AUD | |
2" Trash / Transfer Pump Pump shut-off head (28.0 m) is insufficient to overcome zero-flow static + outlet head (42.0 m). | Petrol | Cannot overcome head | 28 m (275 kPa) | Insufficient Head | $450–$980 AUD |
Bill of Materials (BOM) & Printable Engineering Spec Sheet
Standard Australian poly coil rollup, fitting-system compatibility guard, and counted hardware ready to hand to your rural supply branch.
+ 1 straight coil-to-coil joiner recommended to connect rolls.
Use AS/NZS 4130 Metric DN32 (32 mm OD) external compression or electrofusion fittings. Rural barbed insert fittings will NOT match this pipe's 27 mm bore.
- 1 × 24V / 48V Brushless Solar Submersible Bore Pump$1,400–$3,200 AUDInlet 100 mm / Outlet 32 mm · Shut-off 75 m
- 1 × Spring-Loaded Brass / Stainless Check ValveK=3.20 · 0.12 m
- 3 × Metric PE100 External Compression 90° ElbowK=2.25 · 0.09 m
- 2 × Metric PE100 External Compression JoinerK=0.50 · 0.02 m
- 1 × Full-Bore Quarter-Turn Ball Valve (Fully Open)K=0.15 · 0.01 m
Source Matched Pipe, Fittings & Pumps for This Spec
Links adapt dynamically to your chosen pipe family (DN32 PE100 PN12.5) and active pump category (Solar Bore Pump (24V/48V)).
Off-Grid Solar Bore Kits Sized to Your Total Dynamic Head
Compare 24V/48V brushless submersible kits matched to your calculated head, flow rate, and poly drop-pipe.
AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings
Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.
AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.
24V/48V Solar Bore Daily Yield (L/day) Across 20m–65m Head on DN32 vs DN40 PE100
Solved for a 24V/48V brushless solar submersible bore pump (75 m shut-off, 65 L/min max) feeding an open header tank over 300 m of Metric PE100 PN12.5 at 25°C. Estimated herd size assumes 60 L/head/day.
| Static Head (m) | DN32 PN12.5 Flow (27.0 mm ID) | DN32 Yield (L/day) | DN40 PN12.5 Flow (33.8 mm ID) | DN40 Yield (L/day) | Extra Daily Yield (DN40) |
|---|---|---|---|---|---|
| 20 m (196 kPa) | 42.9 L/min TDH 40.3 m | 14,152 L/day ~235 cattle | 50.7 L/min TDH 29.4 m | 16,736 L/day ~278 cattle | +2,584 L/day |
| 40 m (392 kPa) | 32.8 L/min TDH 52.6 m | 10,825 L/day ~180 cattle | 38.4 L/min TDH 45.7 m | 12,676 L/day ~211 cattle | +1,851 L/day |
| 55 m (539 kPa) | 22.9 L/min TDH 61.7 m | 7,562 L/day ~126 cattle | 27.3 L/min TDH 58.1 m | 9,020 L/day ~150 cattle | +1,458 L/day |
| 65 m (637 kPa) | 14.8 L/min TDH 68.1 m | 4,884 L/day ~81 cattle | 17.0 L/min TDH 66.4 m | 5,623 L/day ~93 cattle | +739 L/day |
Solar Bore Submersible Sizing: System & Pump Curve (300m)
Length: 300 m · Static Rise: 42 m · Darcy-Weisbach (20°C)
Solar Bore Submersible Sizing Field Design Rules
- 1
Use Drawdown Water Level — Not Standing Water Level
Always measure static head from the dynamic pumping water level inside the bore (after sustained pumping drawdown) to the top discharge lip of your elevated header tank.
- 2
Specify Metric PE100 PN12.5 or PN16 Drop Pipe
Submersible bore risers carry both internal head pressure and the suspended weight of water + pump. Use AS/NZS 4130 Blue Stripe PE100 (DN32/DN40 PN12.5 or PN16) plus a stainless safety cable.
- 3
Size Long Paddock Mains One Size Up to Save Solar Watts
Every extra 5–10 m of friction head forces a solar DC pump higher up its H-Q curve, sharply cutting L/day during morning and afternoon shoulder sun hours.
- 4
Allow for 5.5 Peak Sun Hours & Multi-Day Tank Reserve
Design header-tank storage for at least 3–5 days of peak summer stock demand so overcast weather never leaves cattle troughs dry.
Frequently Asked Questions: Solar Bore Submersible Sizing
How many litres per day will a 24V/48V solar submersible bore pump deliver?
Using 5.5 Australian peak sun hours over a 300 m DN40 PE100 PN12.5 line, a typical 24V/48V brushless solar bore pump delivers ~12,676 L/day at 40 m static head (38.4 L/min, supporting ~211 head of cattle) and ~9,020 L/day at 55 m static head.
Should I use DN32 or DN40 Metric PE100 PN12.5 for a solar bore line?
DN32 PE100 PN12.5 (27.0 mm ID) is compact and ideal for the vertical bore drop-pipe and shorter surface runs under 200 m at 15–30 L/min. On 300 m–500 m+ paddock delivery runs at 35–55 L/min, stepping up to DN40 PE100 PN12.5 (33.8 mm ID) reduces friction head by ~68% and preserves extra daily solar yield.
Do solar submersible bore pumps have a 5.5 m suction cavitation limit?
No—because the pump sits submerged below the bore pumping water level, static suction lift is zero. However, you must still keep the pump intake below the bore drawdown level with a dry-run sensor to prevent burning out the rotor/stator.