Off-Grid Solar Stock Water Darcy-Weisbach + Pump Duty-Point Solver

Solar Bore Submersible Pump & Poly Riser Sizing Calculator (AU)

Calculate daily bore yield (L/day at 5.5 peak sun hours), drop-pipe pressure class, and paddock delivery friction.

Blue Stripe · Metric PE100AS/NZS 4130 · OD-Measured

Solar Bore Submersible Sizing

Calculate daily bore yield (L/day at 5.5 peak sun hours), drop-pipe pressure class, and paddock delivery friction.

1. Pipe Standard & Size

44 AU Specs
Measured By
OD (Outer)
True Bore ID
27 mm
Outside OD
32 mm
Max @ 25°C
1163 kPa

OD-measured 32 mm Metric PE100 (AS/NZS 4130, SDR13.6, 1250 kPa at 20°C). Mean ID is 27.0 mm—closer hydraulically to 1" Rural (25.3 mm ID) than to 1 1/4" Rural (31.7 mm ID). Widely used for solar bore risers and high-pressure rural house mains.

2. Site Run & Hydraulic Conditions

L/min

Equivalent: 1,800 L/hr · 43,200 L/24h

1 × 200 m coil + 1 × 100 m coil
m
+412 kPa uphill
m
Total Suction: 0.00 m / 5.5 m max
m
m
KPA
AS/NZS 4130 Derated: 93% → 1163 kPa
°C

Sun-exposed black poly across Australian paddocks regularly exceeds 40°C. At 25°C, DN32 PE100 PN12.5 drops from 1250 kPa to 1163 kPa max (118.5 m head).

3. Fittings & Valves (7)

ΣK = 6.10 · +7.2 m eq. pipe · 0.24 m loss

Suction Intake & Strainer

Directly increases pump suction head — critical for the 5.5 m cavitation & priming guardrail.

Foot Valve & StrainerK=4.5 · 200DHigh suction loss

Highest single fitting loss in typical farm systems due to strainer mesh + hinged/poppet check flap on the suction side—critical for cavitation & 5.5 m suction lift checks! Oversizing suction line by one size cuts this penalty dramatically.

0

Delivery Fittings & Non-Return Valves

Note the steep minor-loss penalty of internal rural barbed inserts vs. full-bore external metric compression fittings.

Rural Barbed JoinerK=1.2 · 55DDifferent fitting systemInternal barb restriction

Internal insert barb steps down inside the pipe wall (reducing local ID by ~4–6 mm), creating sudden contraction/expansion turbulence—nearly 5x the loss of an external metric compression joiner.

0
Rural Barbed 90° ElbowK=1.9 · 85DDifferent fitting systemInternal barb restriction

High minor loss caused by the dual restriction of an internal barbed spigot combined with an abrupt short-radius 90° direction change. Use sweeping pipe bends instead wherever trench layout allows.

0
Rural Barbed Tee (Branch)K=2.4 · 110DDifferent fitting systemInternal barb restriction

Severe bore restriction from internal insert barbs plus 90° dividing/combining branch turbulence. Multiple barbed tees in series rapidly erode available pump head.

0
Metric Compression JoinerK=0.25 · 12D

Full-bore external O-ring and split-ring grip seal—zero internal barb intrusion, keeping velocity profile smooth and minor loss minimal.

Loss: 0.02 m (0.2 kPa · +0.6 m eq.)

2
Metric Compression 90° ElbowK=0.75 · 32D

External compression body preserves full internal bore diameter through the 90° turn, cutting head loss by more than half versus a rural barbed elbow.

Loss: 0.09 m (0.9 kPa · +2.6 m eq.)

3
Metric Compression Tee (Branch)K=1.2 · 55D

Full-bore external seal eliminates barb necking, leaving only the 90° branch turning loss (~half the K-factor of a barbed rural tee).

0
Swing Check ValveK=2 · 90D

Lower head loss than spring-loaded check valves once flow lifts the flap fully open, but slower closure can trigger water-hammer slam on steep rising mains.

0
Spring Check ValveK=3.2 · 140D

Higher resistance due to spring tension and poppet obstruction around the seat, but rapid non-slam closure prevents reverse-flow water hammer on steep hills and bore risers.

Loss: 0.12 m (1.2 kPa · +3.8 m eq.)

1

Isolation Valves

Low friction when fully open; avoid snapping quarter-turn ball valves shut on lines above 1.5 m/s.

Full-Bore Ball ValveK=0.15 · 8D

True full-port ball bore aligns cleanly with pipe ID when open (negligible loss). Warning: never snap quarter-turn valves shut rapidly on high-velocity lines (>1.5 m/s) or severe water hammer will spike pipe pressure.

Loss: 0.01 m (0.1 kPa · +0.2 m eq.)

1
Gate Valve (Open)K=0.2 · 10D

Gate retracts completely clear of the flow path when fully open, giving minimal friction loss. Slow multi-turn closure naturally protects PE poly mains against sudden water-hammer spikes.

0
Australian Supply Match

Source Matched Pipe, Fittings & Pumps for This Spec

Links adapt dynamically to your chosen pipe family (DN32 PE100 PN12.5) and active pump category (Solar Bore Pump (24V/48V)).

Solar Bore SpecialistQuote Partner

Off-Grid Solar Bore Kits Sized to Your Total Dynamic Head

Compare 24V/48V brushless submersible kits matched to your calculated head, flow rate, and poly drop-pipe.

Get Matched Solar Bore Pump Packages
AS/NZS 4130 PE100AU Supplier

AS/NZS 4130 Metric PE100 Blue-Line Pipe & Compression Fittings

Full-bore external metric compression fittings and PN8–PN16 PE100 coils for pressure-rated rural and irrigation mains.

Price 300m of DN32 PE100 PN12.5 + Compression Fittings

AusFlowSpec is independently built for Australian rural water engineering. Some supplier links below are affiliate or quote-referral partners—if you buy or request a quote through them, we may earn a small commission at zero extra cost to you. Engineering calculations are never influenced by partner placement.

Pre-Computed Solar Yield · 5.5 Peak Sun Hours/Day · 300m Delivery

24V/48V Solar Bore Daily Yield (L/day) Across 20m–65m Head on DN32 vs DN40 PE100

Solved for a 24V/48V brushless solar submersible bore pump (75 m shut-off, 65 L/min max) feeding an open header tank over 300 m of Metric PE100 PN12.5 at 25°C. Estimated herd size assumes 60 L/head/day.

Static Head (m) DN32 PN12.5 Flow (27.0 mm ID) DN32 Yield (L/day) DN40 PN12.5 Flow (33.8 mm ID) DN40 Yield (L/day) Extra Daily Yield (DN40)
20 m (196 kPa) 42.9 L/min TDH 40.3 m 14,152 L/day ~235 cattle 50.7 L/min TDH 29.4 m 16,736 L/day ~278 cattle +2,584 L/day
40 m (392 kPa) 32.8 L/min TDH 52.6 m 10,825 L/day ~180 cattle 38.4 L/min TDH 45.7 m 12,676 L/day ~211 cattle +1,851 L/day
55 m (539 kPa) 22.9 L/min TDH 61.7 m 7,562 L/day ~126 cattle 27.3 L/min TDH 58.1 m 9,020 L/day ~150 cattle +1,458 L/day
65 m (637 kPa) 14.8 L/min TDH 68.1 m 4,884 L/day ~81 cattle 17.0 L/min TDH 66.4 m 5,623 L/day ~93 cattle +739 L/day
On-Site Australian Installation Checklist

Solar Bore Submersible Sizing Field Design Rules

  1. 1

    Use Drawdown Water Level — Not Standing Water Level

    Always measure static head from the dynamic pumping water level inside the bore (after sustained pumping drawdown) to the top discharge lip of your elevated header tank.

  2. 2

    Specify Metric PE100 PN12.5 or PN16 Drop Pipe

    Submersible bore risers carry both internal head pressure and the suspended weight of water + pump. Use AS/NZS 4130 Blue Stripe PE100 (DN32/DN40 PN12.5 or PN16) plus a stainless safety cable.

  3. 3

    Size Long Paddock Mains One Size Up to Save Solar Watts

    Every extra 5–10 m of friction head forces a solar DC pump higher up its H-Q curve, sharply cutting L/day during morning and afternoon shoulder sun hours.

  4. 4

    Allow for 5.5 Peak Sun Hours & Multi-Day Tank Reserve

    Design header-tank storage for at least 3–5 days of peak summer stock demand so overcast weather never leaves cattle troughs dry.

Frequently Asked Questions: Solar Bore Submersible Sizing

How many litres per day will a 24V/48V solar submersible bore pump deliver?

Using 5.5 Australian peak sun hours over a 300 m DN40 PE100 PN12.5 line, a typical 24V/48V brushless solar bore pump delivers ~12,676 L/day at 40 m static head (38.4 L/min, supporting ~211 head of cattle) and ~9,020 L/day at 55 m static head.

Should I use DN32 or DN40 Metric PE100 PN12.5 for a solar bore line?

DN32 PE100 PN12.5 (27.0 mm ID) is compact and ideal for the vertical bore drop-pipe and shorter surface runs under 200 m at 15–30 L/min. On 300 m–500 m+ paddock delivery runs at 35–55 L/min, stepping up to DN40 PE100 PN12.5 (33.8 mm ID) reduces friction head by ~68% and preserves extra daily solar yield.

Do solar submersible bore pumps have a 5.5 m suction cavitation limit?

No—because the pump sits submerged below the bore pumping water level, static suction lift is zero. However, you must still keep the pump intake below the bore drawdown level with a dry-run sensor to prevent burning out the rotor/stator.